欢迎访问ic37.com |
会员登录 免费注册
发布采购

BC352R110T060VM-00 参数 Datasheet PDF下载

BC352R110T060VM-00图片预览
型号: BC352R110T060VM-00
PDF下载: 下载PDF文件 查看货源
内容描述: BCM阵列™ [BCM Array™]
分类和应用:
文件页数/大小: 6 页 / 328 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BC352R110T060VM-00的Datasheet PDF文件第1页浏览型号BC352R110T060VM-00的Datasheet PDF文件第2页浏览型号BC352R110T060VM-00的Datasheet PDF文件第3页浏览型号BC352R110T060VM-00的Datasheet PDF文件第5页浏览型号BC352R110T060VM-00的Datasheet PDF文件第6页  
THERMALS AND PIN CONTROL FUNCTIONS
700
600
500
Output Power (W)
200 LFM
400
400 LFM
300
600 LFM
200
800 LFM
Power Limit
100
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Ambient Temperature (ºC)
Figure 1
– BC352R110T060VM-00 typical thermal curve – verify all thermal management systems experimentally.
CNTRL – Enable / Disable
The Enable / Disable signal is a multifunction node that provides the
following functions:
Enable / Disable – If CNTRL is left floating, the module output is
enabled. Once this port is pulled lower than 2.4 Vdc with respect to
–In, the output is disabled. This action can be realized by employing
a relay, opto-coupler, or open collector transistor. This signal should
not be toggled at a rate higher than 1 Hz. CNTRL should also not be
driven by or pulled up to an external voltage source.
Primary Auxiliary Supply – CNTRL can source up to 2.4 mA at
5.0 Vdc. CNTRL should never be used to sink current.
Alarm – The module contains circuitry that monitors output
overload, input over voltage or under voltage, and internal junction
temperatures. In response to an abnormal condition in any of the
monitored parameters, CNTRL
will toggle.
Figure 2
— Temp measurement location
+In / -In – DC Voltage Input Ports
The BCM Array input voltage range should not be exceeded. An
internal under / over voltage lockout-function prevents operation
outside of the normal operating input range. The module turns on
within an input voltage window bounded by the “Input under-
voltage turn-on” and “Input over-voltage turn-off” levels, as
specified. The module may be protected against accidental
application of a reverse input voltage by the addition of a rectifier in
series with the positive input, or a reverse rectifier in shunt with the
positive input located on the load side of the input fuse.
+Out / -Out – DC Voltage Output Ports
Multiple pins are provided for the +Out and –Out connections.
They must be connected in parallel with low interconnect resistance.
The low output impedance of the module reduces or eliminates the
need for limited life aluminum electrolytic or tantalum capacitors at
the input of POL converters.
Total load capacitance at the output of the device should not exceed
the specified maximum. Owing to the wide bandwidth and low
output impedance of the BCM Array, low frequency bypass
capacitance and significant energy storage may be more densely
and efficiently provided by adding capacitance at the input.
VI BRICK BCM Array
BC352R110T060VM-00
vicorpower.com
Rev. 1.0
Page 4 of 6