PRELIMINARY  
V•I Chip Bus Converter Module  
Application Note (continued)  
Input Impedance Recommendations  
Input Fuse Recommendations  
To take full advantage of the BCM capabilities, the impedance presented  
to its input terminals must be low from DC to approximately 5 MHz. The  
source should exhibit low inductance (less than 100 nH) and should have a  
critically damped response. If the interconnect inductance exceeds 100 nH,  
the BCM input pins should be bypassed with an RC damper (e.g., 100 µF  
in series with 0.3 ohm) to retain low source impedance and stable  
operations. Given the wide bandwidth of the BCM, the source response is  
generally the limiting factor in the overall system response.  
V•I Chips are not internally fused in order to provide flexibility in  
configuring power systems. However, input line fusing of V•I Chips must  
always be incorporated within the power system. A fast acting fuse should  
be placed in series with the +IN port.  
Anomalies in the response of the source will appear at the output of the  
BCM multiplied by its K factor. The DC resistance of the source should be  
kept as low as possible to minimize voltage deviations. This is especially  
important if the BCM is operated near low or high line as the over/under  
voltage detection circuitry could be activated.  
Application Circuits  
Vo = 4.75 - 6.87 V  
+Out  
-Out  
+In  
TM  
RSV  
PC  
48 Vin  
(38 - 55 Vdc)  
BCM  
+Out  
K
Ro  
-In  
-Out  
NiPOL  
1
NiPOL  
2
NiPOL  
3
NiPOL  
4
LOAD  
1
LOAD  
2
LOAD  
3
LOAD  
4
Figure 27—The BCM provides an isolated output from a narrow range input ideal for driving non-isolated point of load converters (niPOLs)  
In the following figure;  
K = BCM Transformation Ratio  
RO = BCM Output Resistance  
VO = BCM Output  
Vf = PRM Output (Factorized Bus Voltage)  
VL = Desired Load Voltage  
VS = PRM Output Set Point Voltage  
FPA Local Loop  
Vo = VL – IO • RO  
VH  
SC  
SG  
OS  
NC  
VC  
PC  
TM  
IL  
+Out  
+In  
ROS  
Factorized  
Power Bus  
L
O
A
D
NC  
PR PRM-AL CD  
-Out  
TM  
BCM  
RSV  
+In  
+Out  
PC  
+Out  
VL  
Vf =  
K
48 Vin  
(36 - 75 Vdc)  
K
Ro  
-In  
–In  
–Out  
-Out  
VS range = 38 - 55 Vdc  
B048K060T24  
(K = 1/8 : RO = 5.5 m)  
Figure 28—The PRM regulates its output to provide a constant factorized bus voltage. The output voltage is the nominal load voltage, Vo, at no  