Performance SpecicaƟons (connued)  
Industrial GPS Receiver (MIL-P (Y) code as an opon)  
L1 frequency (1575 MHz), C/A code 12 parallel tracking channels  
L1/L2 frequency P(Y) code SAASM 12 parallel tracking channels as an opon (For more informaon contact factory)  
Tracking  
PosiƟon  
Lat., long., alt.  
6m CEP (50%) w/o SA  
PosiƟon Accuracy ( Lat long )  
PosiƟon Accuracy ( Alt )  
GPS Antenna DC Voltage  
AcquisiƟon Time  
11m CEP (50%) w/o SA  
5V  
Warm start 45 second, Cold start < 50 second (worst case)  
Dimensions & Weight  
245 mm (w) x 166 mm (h) x 56 mm (d)  
1.5 Kg  
Dimensions  
weight  
Environmental  
Operang:-25°C to +65°C (-40°C to +65°C Opt.)  
Emergency: +71°C for 60 minutes  
Storage: -40°C to +71°C  
Temperature  
Temperature AlƟtude  
-40°C to +65°C (+71°C for 60 minutes) 0 to 60,000 ꢃ  
95% non condensing  
Humidity  
2.45gRMS as per the following prole:  
Random VibraƟon  
(Without vibraƟon absorbers. For more details on  
the vibraƟon absorbers opƟon – please see the  
Accessories chapter below)  
Mechanical Shock - OperaƟon  
Mechanical Shock - crash  
Bench Handling Shock  
Rain  
MIL-STD-810C/E, Method 516.2, Proc. 1 (15g / Half sine/ 3 axis/ 6 shocks per axis(  
X-40G, Y-15G, Z-20G, 11ms, Half Sine, Total 12 shocks  
MIL-STD-810C/E, Method 516.2, Procedure V  
MIL-STD-810E Method 506.3 procedure I  
Dust  
MIL-STD-810E Method 510.3  
Salt Atmosphere  
Bonding  
MIL-STD-810E, Method 509.3, Procedure I  
2.5 mꢅ  
EMI / RFI  
MIL-STD-461B/C Part: 5 (CE01, CE03, CE07, RE02, CS01, CS02, CS06, RS02, RS03)  
Reliability, Maintainability, Testability  
> 20,000 hours @ 30°C, ARW, MIL-HBK-217F  
MTBF  
MTTR – O Level  
MTTR – I Level  
BIT (Built In Test)  
12 min. to replace failed unit (including warm-up time)  
34 min. to replace failed module (including warm-up me)  
On-line BIT – Automac, Covers 90% of all failures  
Page 3 of 8  
Rev 1.0 Oct 2014  
Vectron Internaonal • 267 Lowell Road, Suite 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • hp://www.vectron.com