Performance SpecicaƟons  
All specicaons are at room temperature, quiescent condions, sea level ambient unless otherwise specied  
Input & Outputs  
1 x 10MHz, Sine wave (8±3) dBm SMA / 50Ω  
2 X 1PPS TTL/50Ω  
5 x 1PPS ICD-GPS-060/ 50(10V, 20s)  
4 x 1PPS RS-422  
GPS Ant.  
5x TOD H.Q.  
5x 1PPS PTTI  
4x 1PPS RS-422  
1x 1PPS TTL/50Ω  
CLI RS-422  
J4  
J2  
Outputs  
Input  
AUX: 1PPS TTL/50or other signal (opt.)  
5 X TOD ICD-GPS-060 / 100Kꢅ  
1PPS PTTI  
J2  
TOD H.Q.  
CLI RS-232  
TOD ICD-GPS-060 TTL/100K ꢅ  
GPS Antenna  
Overall BIT  
GPS Crypto Keys  
MUX-BUS Address (opt)  
AR-51-07  
External 1 PPS ICD-GPS-060/ 50or TTL/50(see opon 4)  
CLI RS232 (input/output) for control and monitoring: seng me/date, delay  
correcon for 1PPS 10ns steps, mode of operaon; disciplining to GPS/Ext  
1PPS, holdover, UTC me, GPS Time, Local Time, Day Light Saving etc. (see CLI  
document for more informaon).  
AUX OUT: 1PPS RAW  
10MHz/50Ω  
J5  
J6  
NTP/MUX-BUS (opt)  
22-32 VDC  
J3  
J1  
Baud rate: 19,200, Control: 1, N, 8  
CommunicaƟon  
CLI RS422 (the Input (RXD) can not be connected simultaneously with the RS232).  
Opon: LAN – NTP / MIL- STD-1553RT (MUX-BUS)  
1PPS TTL/50Ω  
J7  
GUI for PC is available :Time, Date, Posion, Status, BIT (Built in test) etc.  
Performance  
Disciplined to GPS or to an External synchronizaon source 50ns RMS (typ. 20ns RMS) @ 25°C, relave to an external ref.  
Time (1PPS)  
Long Term Accuracy  
Long Term Stability  
Time Driwithout GPS (Hold-Over)  
Disciplined to GPS or to Ext. 1PPS  
Free running Rubidium-Standard  
< 1μs/24hr (Typ.)  
< 2E-12 (24 hour average, const temp.)  
5E-11 / month drift in holdover  
Short Term Stability  
Temperature Stability  
4E-11 @ 1s (3E-11 Typ.)  
±3E-10 over -25°C to +65°C (-40°C opt.)  
Frequency  
1Hz  
Standard (spec)  
Standard (typical)  
Improved (typical)  
-96/Hz  
10Hz  
100Hz  
1KHz  
-100dBc/Hz  
-134dBc/Hz  
-143dBc/Hz  
-145dBc/Hz  
-101dBc/Hz  
-137dBc/Hz  
-144dBc/Hz  
-149dBc/Hz  
-128/Hz  
Phase Noise  
-148/Hz  
Frequency  
(10MHz)  
-150/Hz  
10KHz  
-153/Hz  
Harmonics  
Spurious  
-45 dBc (-58 dBc typ.)  
<-75 dBc @ ± 100KHz from carrier  
Rb Lock < 4 min  
5E-10 within < 7 min  
5E-11 within < 60 min,  
1E-11 within < 4hrs  
2E-12 within < 24 hrs.  
Warm-up  
Retrace  
± 4E-11  
Power Supply  
Input Voltage  
Power  
22-32 VDC (28 VDC Typ.) per MIL-STD-704D  
< 30 Watt @ 28 VDC ( warm-up)  
< 14 Wa@ 28 VDC @ 25°C (steady-state)  
External power input for baery back-up via the main power inlet  
Automacally operated when the main power reduces to 24 VDC  
BaƩery Back-Up  
Page 2 of 8  
Rev 1.0 Oct 2014  
Vectron Internaonal • 267 Lowell Road, Suite 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • hp://www.vectron.com