DC/DC Converters
THL 10WI Series
10 Watt
Outline Dimensions
7.62
(0.3)
5.08
(0.2)
Pin-Out
Pin
1
Single
+Vin (Vcc)
–Vin (GND) –Vin (GND)
Dual
1
2
6
+Vin (Vcc)
2
Bottom view
4
3
+ Vout
No pin
–Vout
+ Vout
Common
–Vout
3
5
4
5
10.16 10.16
(0.4)
2.5
(0.1)
6.0
(0.24)
10.2
(0.4)
(0.4)
6
Remote On/Off
25.4
(1.0)
Dimensions in [mm], () = Inch
Pin diameter ø 1.0 (0.04)
Pin pitch tolerances: 0.25 ( 0.01)
Tolerances: 0.5 ( 0.02)
Heat-Sink (Option)
Order code: THL-HS1
(cont.: heat-sink, thermal pad, 2 clamps)
Aluminum
Anodic treatment (black)
4.0 g (0.14oz) without converter
Material:
Finish:
Weight:
Thermal impedance after assembling: 15.8 K/W
31.0 (1.22) max.
Heat-sink
Thermal pad
Clamp
Note:
The product label on converter has to be re-
moved before mounting the heat-sink.
For volume orders converters will be sup-
plied with heat-sink already mounted. Please
contact factory for quotation.
Converter
17.5 (0.69)
max.
Separate heat-sinks are only available for
prototypes and small quantity orders.
Specifications can be changed any time without notice.
Rev. 06/12.1
Jenatschstrasse 1 · CH-8002 Zurich · Switzerland
Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · info@traco.ch · www.tracopower.com