DC/DC Converters
THL 10WI Series
10 Watt
General Specifications
Temperature ranges
– Operating without heat sink
– Operating with heat sink
– Case temperature
– Storage
–40°C to +75°C (with derating)
–40°C to +85°C (with derating)
+100°C max.
–40°C to +125°C
Power derating
– Operating without heat sink
– Operating with heat sink
2.5 %/K above +60°C
3.5 %/K above +70°C
Thermal inpedance
Humidity (non condensing)
– Natural convection
– Natural convection with heat sink
18.2°C/W
15.8°C/W
95 % rel H max.
>350’000 h
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign)
Isolation voltage (60 sec.) – Input/Output
1’500 VDC
Isolation capacitance
Isolation resistance
Remote On/Off
– Input/Output
1200 pF max.
– Input/Output (500 VDC)
>1’000 MOhm
– On:
2.5 ... 50 VDC or open circuit
– Off:
– Off idle current:
0 ... +1.0 VDC or short circuit pin 6 and pin 2
10 mA max.
Switching frequency (fixed)
Altitude during operation
Safety standards
400 kHz typ. (pulse width modulation PWM)
5‘000 m max. (16‘400 ft) approved
UL/cUL 60950-1, IEC/EN 60950-1
Safety approvals
– UL/cUL
www.ul.com -> File no. e188913
(entry pending)
– CB test certificate according IEC 60950-1
– CSA certificate for UL/cUL 60950-1
www.tracopower.com/products/thl10wi-cb.pdf
www.tracopower.com/products/thl10wi-csa.pdf
Environmental compliance – Reach
www.tracopower.com/products/thl10wi-reach.pdf
RoHS directive 2002/95/EC
– RoHS
Physical Specifications
Casing material
Baseplate
metal
non conductive FR4
epoxy (UL 94V-0 rated)
15 g (0.53oz)
Potting material
Weight
Soldering temperature
max. +260°C / 10sec.
Application note : www.tracopower.com/products/thl10wi-application.pdf
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 4