MIDR03M SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
Total Power International, Inc.
Output Specifications
Parameter
Conditions
Min.
---
Typ.
---
Max.
±4.0
±4.0
±0.5
Unit
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
At 50% Load and Nominal Vin
Dual Output, Balanced Loads
Vin=Min. to Max.
%Vnom.
---
±2.0
±0.3
%
%
%
---
Load Regulation
Io=10% to 100%
---
±0.5
±1.0
Min.Load
No minimum Load Requirement
Ripple & Noise
max. 20MHz Bandwidth
---
---
30
50
mV P-P
Temperature Coefficient
Short Circuit Protection
±0.01
±0.02
%/℃
Continuous
Isolation, Safety Standards
Parameter
Conditions
60 Seconds
Min.
3000
4500
---
Typ.
---
Max.
---
Unit
VACrms
VPK
I/O Isolation Voltage (reinforced)
I/O Isolation Test Voltage
Leakage Current
Flash tested for 1 Second
240VAC, 60Hz
500 VDC
---
---
---
2
μA
I/O Isolation Resistance
I/O Isolation Capacitance
10
---
---
GΩ
100KHz, 1V
---
20
---
pF
cUL/UL60950-1, CSA C22.2 No. 60950-1-03
Safety Standards
UL60601-1,CSA C22.2 No.601-1,
IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition, 2 MOOP
IEC60950-1 CB report, cUL/UL 60950-1 certificate
UL60601-1 UL certificate
Approvals(Pending)
General Specifications
Parameter
Conditions
Min.
25
Typ.
60
Max.
Unit
KHz
Switching Frequency
MTBF(calculated)
---
---
MIL-HDBK-217F@25℃, Ground Benign
1,000,000
---
Hours
Input Fuse
5V Input Models
12V Input Models
24V Input Models
2000mA Slow-Blow Type
1000mA Slow-Blow Type
500mA Slow-Blow Type
Environmental Specifications
Parameter
Conditions
Min.
-40
---
Max.
+75
+95
+125
95
Unit
℃
Natural Convection
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
℃
-50
---
℃
Storage Temperature Range
Humidity (non condensing)
% rel. H
Cooling
Free-Air convection
---
Lead Temperature (1.5mm from case for 10Sec.)
260
℃
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com