欢迎访问ic37.com |
会员登录 免费注册
发布采购

73S8024RN-20IMR/F 参数 Datasheet PDF下载

73S8024RN-20IMR/F图片预览
型号: 73S8024RN-20IMR/F
PDF下载: 下载PDF文件 查看货源
内容描述: 低成本智能卡接口 [Low Cost Smart Card Interface]
分类和应用: PC
文件页数/大小: 27 页 / 390 K
品牌: TERIDIAN [ TERIDIAN SEMICONDUCTOR CORPORATION ]
 浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第4页浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第5页浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第6页浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第7页浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第9页浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第10页浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第11页浏览型号73S8024RN-20IMR/F的Datasheet PDF文件第12页  
73S8024RN Data Sheet  
DS_8024RN_020  
3 Power Supply and Voltage Supervision  
The 73S8024RN smart card interface IC incorporates a LDO voltage regulator. The voltage output is  
controlled by the digital input 5V/#V. This regulator is able to provide either 3V or 5V card voltage from  
the power supply applied on the VPC pin.  
Digital circuitry is powered by the power supply applied on the VDD pin. VDD also defines the voltage  
range to interface with the system controller.  
Three voltage supervisors constantly check the presence of the voltages VDD, VPC and VCC. A card  
deactivation sequence is forced upon fault of any of these voltage supervisors. The two voltage  
supervisors for VPC and VCC are linked so that a fault is generated to activate a deactivation sequence  
when the voltage VPC becomes lower than VCC. It allows the 73S8024RN to operate at lower VPC voltage  
when using 3V cards only. The voltage regulator can provide a current of at least 90mA on VCC that  
comply easily with EMV 4.0 and NDS specifications. The VPC voltage supervisor threshold values are  
defined from applicable standards (EMV and NDS). A third voltage supervisor monitors the VDD voltage.  
It is used to initialize the ISO-7816-3 sequencer at power-on, and to deactivate the card at power-off or  
upon fault. The voltage threshold of the VDD voltage supervisor is internally set by default to 2.3V  
nominal. However, it may be desirable, in some applications, to modify this threshold value. The pin  
VDDF_ADJ (pin 18 in the SO package, pin 17 in the 32QFN package, not supported in the 20QFN  
package) is used to connect an external resistor REXT to ground to raise the VDD fault voltage to another  
value VDDF. The resistor value is defined as follows:  
REXT= 56k/(VDDF - 2.33)  
An alternative method (more accurate) of adjusting the VDD fault voltage is to use a resistive network of  
R3 from the pin to supply and R1 from the pin to ground (see applications diagram). In order to set the  
new threshold voltage, the equivalent resistance must be determined. This resistance value will be  
designated Kx. Kx is defined as R1/(R1+R3). Kx is calculated as:  
Kx = (2.789 / VTH) - 0.6125 where VTH is the desired new threshold voltage.  
To determine the values of R1 and R3, use the following formulas.  
R3 = 24000 / Kx  
R1 = R3*(Kx / (1 – Kx))  
Taking the example above, where a VDD fault threshold voltage of 2.7V is desired, solving for Kx gives:  
Æ Kx = (2.789 / 2.7) - 0.6125 = 0.42046.  
Solving for R3 gives:  
Solving for R1 gives:  
Æ R3 = 24000 / 0.42046 = 57080.  
Æ R1 = 57080 *(0.42046 / (1 – 0.42046)) = 41412.  
Using standard 1 % resistor values gives R3 = 57.6KΩ and R1 = 42.4KΩ.  
These values give an equivalent resistance of Kx = 0.4228, a 0.6% error.  
If the 2.3V default threshold is used, this pin must be left unconnected. The 20QFN package has the VDD  
fault threshold fixed at this default value.  
8