HV300  
___________________________________________________________________________________________  
Typical Application Circuit  
Long  
Pin  
GND  
8
Jumper  
Short  
VDD  
Pin  
GND  
PWRGD  
1
487K R1  
9.09K R2  
9.09K R3  
ENABLE  
3
2
UV  
OV  
+5V  
DC/DC  
PWM  
CONVERTER  
Cload  
HV300  
COM  
RAMP  
7
VEE  
4
SENSE  
GATE  
6
5
NOTES: 1. Undervoltage Lockout (UV) set to 35V.  
2. Overvoltage Lockout (OV) set to 65V.  
3. Remove Jumper if Short Pin is used.  
10nF  
C1  
Long  
Pin  
-48V  
R4  
Q1  
0.05  
IRF530  
Application Information  
Under Voltage and Over Voltage Detection  
Current Limit  
The UV and OV pins are connected to comparators with nominal  
The current limit magnitude above which the current will not be  
allowed to rise during startup is programmed using a sense resistor  
connected from the SENSE pin to VEE pin. For example to  
program a current limit of 1A, one would choose a resistor as  
follows:  
1.21V thresholds and 100mV of hysteresis (1.21V ± 50mV). They  
are used to detect under voltage and over voltage conditions at the  
input to the circuit. Whenever the OV pin rises above its threshold  
or the UV pin falls below its threshold the GATE voltage is  
immediately pulled low, the PWRGD pin is pulled low and the  
external capacitor connected to the RAMP pin is discharged.  
Rsense = 50mV / Isense  
Rsense = 50mV / 1A  
Rsense = 50mΩ  
The under voltage and over voltage trip points can be programmed  
by means of the three resistor divider formed by R1, R2 and R3.  
Since the input currents on the UV and OV pins are negligible the  
resistor values may be calculated as follows:  
UV = VUVH = 1.26 = VEEUV * (R2+R3) / (R1+R2+R3)  
OV = VOVL = 1.16 = VEEOV * R3 / (R1+R2+R3)  
Where VEEUV and VEEOV are Under & Over Voltage Set points.  
If we select a divider current of 100µA at a nominal operating input  
voltage of 50 Volts then  
(R1+R2+R3) = 50V / 100µA = 500K Ohms  
From the second equation for an Over voltage set point of 65 Volts  
the value of R3 may be calculated.  
OV = 1.16 = 65 * R3 / 500K  
R3 = (1.16 * 500K) / 65; Let R3 = 9K  
From the first equation for an Under Voltage set point of 35 Volts the  
value R2 can be calculated.  
UV = 1.26 = 35 * (R2 + R3) / 500K  
R2 = (1.26 * 500K) / 35 – 9K  
R2 = 9K  
Then R1 = 500K – (R2 +R3); R1 = 482K  
Prepared by the Telecom Group  
5 of 5  
Rev. E  
7/19/2001  