HV219
Electrical Characteristics
AC Characteristics(over recommended operating conditions, VDD=5.0V, unless otherwise noted)
Sym
Parameter
0°C
+25°C
Typ
+70°C
Unit Conditions
s
Min
Max
Min
Max
Min
Max
tSD
150
150
150
150
ns
ns
Set Up Time Before LE Rises
tWLE
150
150
Time Width of LE
tDO
twCL
tSU
Clock Delay Time to Data out
Time Width of CL
Set Up Time Data to Clock
Hold Time Data from Clock
150
150
150
ns
ns
ns
ns
150
15
35
150
15
35
150
20
35
8.0
tH
50% duty cycle,
DATA = fCLK/2
fCLK
tr,tf
Clock Frequency
Clock rise and fall Times
Turn on Time
5.0
50
5.0
50
5.0
50
MHz
ns
f
VSIG = VPP-10V,
RLOAD = 10KΩ
VSIG = VPP-10V,
RLOAD = 10KΩ
VPP = +40V,
Ton
5.0
5.0
5.0
µs
Toff
Turn off Time
5.0
20
20
20
5.0
20
20
20
5.0
20
20
20
µs
VNN = -160V
VPP = +100V,
dv/dt
Maximum VSIG Slew Rate
VNN = -100V
VPP = +160V,
VNN = -40V
V/ns
dB
F = 5MHz, 1KΩ//15pF
load
F = 5.0MHz, 50Ω load
F = 5.0MHz, 50Ω load
300ns pulse width, 2.0%
duty cycle
-30
-58
-30
-33
-30
-58
KO
Off Isolation
-58
-60
Kcr
Iid
Switch Crosstalk
Output Switch Isolation Diode
Current
dB
300
300
300
mA
CSG(off) Off Capacitance SW to Gnd
CSG(on) On Capacitance SW to Gnd
14
40
25
60
14
40
20
50
25
60
14
40
25
60
pF
pF
0V, f = 1MHz
0V, f = 1MHz
VPP = +40V,
+VSPK
150
mV
V
NN = -160V,
LOAD = 50ohm
VPP = +100V,
NN = -100V,
LOAD = 50ohm
-VSPK
200
R
+VSPK
150
200
150
200
mV
V
R
Output Voltage Spike
-VSPK
V
V
PP = +160V,
NN = -40V,
+VSPK
-VSPK
mV
pC
R
LOAD = 50ohm
VPP = +40V,
NN = -160V,
SIG = 0V
VPP = +100V,
1450
1050
V
V
V
V
NN = -100V,
SIG = 0V
Q
Charge Injection
VPP = +160V,
550
V
V
NN = -40V,
SIG = 0V
A042705