SMM764  
Preliminary Information  
SEQUENCE POSITION  
3
1
2
4
VDD (+2.7V to +5.5V)  
or 12VIN ( +8V to +15V)  
2.5V  
1.8V  
1.5V  
1.2V  
Figure 2 – Example power supply sequencing and system start-up initialization using the SMM764. Cascade  
sequencing ensures that all supplies in the previous sequence position are valid before the next channel is  
released. Using the SMM764 any order of supply sequencing can be applied.  
GENERAL DESCRIPTION  
The SMM764 is a highly integrated and accurate  
power supply controller, monitor, and sequencer. Each  
device has the ability to automatically control, monitor  
and cascade sequence up to 4 power supplies. In  
addition, the SMM764 includes Sequence-Linka  
feature that allows for the seamless integration of  
other Sequence-Link devices to accommodate  
sequencing of up to 46 channels. The SMM764 can  
monitor the VDD input, the 12V input, two general-  
purpose analog inputs, and the internal temperature  
sensor. The SMM764 has four operating modes:  
power-on sequencing modes, monitor mode, supply  
margining mode using Active DC Output Control  
(ADOCTM), and power-off sequencing mode.  
reference). The part also enables the triggering of  
outputs by monitored fault conditions. The 10-bit ADC  
cycles through all 9 channels every 2ms and checks  
the conversions against the programmed threshold  
limits. The results can be used to trigger RST#,  
HEALTHY and FAULT# outputs as well as to initiate a  
Fault-Triggered  
operation.  
power-off  
or  
force-shutdown  
While the SMM764 is in its monitoring mode, an I2C  
command to margin the supply voltages can bring the  
part into margining mode. In margining mode the  
SMM764 can margin 4 supply voltages in any  
combination of nominal, high and low voltage settings  
using the ADOC feature, all to within ±0.2% using a  
±0.1% external reference. The margin high and low  
voltage settings can range from 0.3V to VDD around  
the converters’ nominal output voltage setting  
depending on the specified margin range of the DC-  
DC converter. During this mode the HEALTHY output  
is always active and the RST# output is always  
inactive regardless of the voltage threshold limit  
settings and triggers. Furthermore, the triggers for  
power-off and force-shutdown are temporarily  
disabled.  
Power-on sequencing is initiated by the rising edge of  
the PWR_ON pin. During power-on sequencing the  
SMM764 will sequence the power supply channels on,  
in any order, by activating the PUP outputs and  
monitoring the respective converter voltages to ensure  
cascading of the supplies. Cascade sequencing is the  
ability to hold off the next sequenced supply until the  
first supply reaches a programmed threshold. A  
programmable sequence termination timer can be set  
to disable all channels if the power-on sequence stalls.  
Once all supplies have sequenced on and the voltages  
are above the UV settings, the ADOC, if enabled, will  
bring the supply voltages to their nominal settings.  
During this mode, the HEALTHY output will remain  
inactive and the RST# output will remain active.  
Once the power-on sequencing mode is complete, the  
SMM764 enters monitor mode. In the monitor mode,  
the SMM764 starts the ADOC control of the supplies  
and adjusts the output voltage to the programmed  
setting under all load conditions, especially useful for  
supplies without sense lines. Typical converters have  
±2% accuracy ratings for their output voltage; the  
ADOC feature of the SMM764 increases the accuracy  
to ±0.2% (using a ±0.1% external voltage  
The power-off sequencing mode can only be entered  
while the SMM764 is in the monitoring mode. It can  
be initiated by either bringing the PWR_ON pin low,  
through I2C control, or triggered by a channel  
exceeding its programmed thresholds. Once power-  
off is initiated, it will disable the ADOC function and  
sequence the PUP outputs off in the reverse order as  
power-on sequencing. To ensure cascading of the  
supplies during power-off sequencing all supplies will  
be monitored as they turn off.  
The sequence  
termination timer can be programmed to immediately  
disable all channels if the power-off sequencing stalls  
via a force-shutdown operation.  
Summit Microelectronics, Inc  
2098 1.1 6/29/2005  
3