HDIF45A10DC 参数 Datasheet PDF下载

HDIF45A10DC图片预览
型号: HDIF45A10DC
PDF下载: 下载PDF文件 查看货源
内容描述: SAW滤波器 [SAW FILTER]
分类和应用: LTE
文件页数/大小: 9 页 / 303 K
品牌: SHOULDER [ SHOULDER ELECTRONICS LIMITED. ]
 浏览型号HDIF45A10DC的Datasheet PDF文件第1页浏览型号HDIF45A10DC的Datasheet PDF文件第2页浏览型号HDIF45A10DC的Datasheet PDF文件第3页浏览型号HDIF45A10DC的Datasheet PDF文件第4页浏览型号HDIF45A10DC的Datasheet PDF文件第6页浏览型号HDIF45A10DC的Datasheet PDF文件第7页浏览型号HDIF45A10DC的Datasheet PDF文件第8页浏览型号HDIF45A10DC的Datasheet PDF文件第9页  
SAW FILTER  
HDIF45A10Dc SIP5Dc  
3.1 Maximum Rating  
DC voltage  
AC voltage  
VDC  
Vpp  
12  
10  
V
V
Between any terminals  
Between any terminals  
3.2 Electrical Characteristics  
Source impedance  
Load impedance  
ZS=50Ω  
ZL=2kΩ//3pF  
Freq  
TA=25℃  
Min  
9.4  
typ  
max  
Insertion attenuation  
44.00MHz  
11.4  
13.4  
dB  
Reference level  
45.75MHz  
42.17MHz  
41.25MHz  
39.75MHz  
47.25MHz  
3.6  
3.7  
5.1  
5.2  
6.6  
6.7  
21.7  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
ppm/k  
Relative attenuation  
17.7  
42.0  
41.0  
35.0  
35.0  
19.7  
55.0  
48.0  
41.0  
40.0  
-72  
35.00~39.75MHz  
47.25~55.00MHz  
Temperature coefficient  
Sidelobe  
3.3 Environmental Performance Characteristics  
Item  
High  
temperature  
Condition  
Specifications  
The specimen shall be store at a temperature of  
80±2℃ for 96±4h. Then it shall be subjected to  
standard atmospheric conditions for 1h, after  
which measurement shall be made within 1h.  
The specimen shall be store at a temperature of  
-20±3℃ for 96±4h. Then it shall be subjected to  
standard atmospheric conditions for 1h, after  
which measurement shall be made within 1h.  
The specimen shall be store at a temperature of  
40±2with relative humidity of 90% to 96%  
for 96±4h. Then it shall be subjected to standard  
atmospheric conditions for 1h, after which  
measurement shall be made within 1h.  
Mechanical  
characteristics and  
specifications  
electrical  
characteristics shall  
be satisfied. There  
Low  
temperature  
in  
Humidity  
shall  
be  
no  
excessive change in  
appearance.  
Thermal  
shock  
The specimen shall be subjected to 8 continuous  
cycles each as shown below. Then it shall be  
subjected to standard atmospheric conditions for  
1h, after which measurement shall be made  
within 1h.  
www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:info@shoulder.cn  
Page 5 of 9