E0C6S37
■ ELECTRICAL CHARACTERISTICS
● Absolute Maximum Ratings
(VDD=0V)
Rating
Supply voltage
Symbol
VSS
Value
-5.0 to 0.5
Unit
V
Input voltage (1)
Input voltage (2)
Permissible total output current *1 ΣIVSS
Operating temperature
Storage temperature
Soldering temperature / Time
Permissible dissipation *2
VI
VIOSC
VSS - 0.3 to 0.5
VSS - 0.3 to 0.5
10
-20 to 70
-65 to 150
V
V
mA
°C
°C
–
Topr
Tstg
Tsol
PD
260°C, 10sec (lead section)
250
mW
1: The permissible total output current is the sum total of the current (average current) that simultaneously flows from the output pins (or is draw in).
2: In case of plastic package (QFP6-60pin).
● Recommended Operating Conditions
E0C6S37
(Ta=-20 to 70°C)
Condition
Symbol
Remark
Min.
-3.6
Typ.
-3.0
32.768
65
Max.
-1.8
Unit
V
Supply voltage
Oscillation frequency
V
f
f
SS
V
DD=0V
OSC1 Crystal oscillation
OSC2 CR oscillation, R=470kΩ
kHz
kHz
µF
50
0.1
0.1
0.1
0.1
0.1
80
Booster capacitor
C1
C2
C3
C4
C5
Capacitor between VDD and VL1
Capacitor between VDD and VL2
Capacitor between VDD and VL3
Capacitor between VDD and VS1
µF
µF
µF
µF
E0C6SL37
(Ta=-20 to 70°C)
Condition
Supply voltage
Symbol
VSS
Remark
Min.
-2.0
-2.0
Typ.
-1.5
-1.5
Max.
-1.1
-0.9 *2
Unit
V
V
VDD=0V *3
VDD=0V, With software control *1
Oscillation frequency
fOSC1 Crystal oscillation
fOSC2 CR oscillation, R=470kΩ
32.768
65
kHz
kHz
µF
µF
µF
µF
µF
50
0.1
0.1
0.1
0.1
0.1
80
Booster capacitor
C1
C2
C3
C4
C5
Capacitor between VDD and VL1
Capacitor between VDD and VL2
Capacitor between VDD and VL3
Capacitor between VDD and VS1
1: When the heavy load protection mode is set by software and the SVD circuit is turned off. Cannot be operated when the CR
oscillation circuit is used.
2: The voltage which can be displayed on the LCD panel will differ according to the characteristics of the LCD panel.
3: When there is no software control during CR oscillation or crystal oscillation.
E0C6SB37
(Ta=-20 to 70°C)
Condition
Supply voltage
Symbol
VSS
Remark
Min.
-3.6
-3.6
Typ.
-1.5
-1.5
Max.
-1.1
-0.9 *2
Unit
V
V
VDD=0V *3
VDD=0V, With software control *1
Oscillation frequency
fOSC1 Crystal oscillation
fOSC2 CR oscillation, R=470kΩ
32.768
65
kHz
kHz
µF
µF
µF
µF
µF
50
0.1
0.1
0.1
0.1
0.1
80
Booster capacitor
C1
C2
C3
C4
C5
Capacitor between VDD and VL1
Capacitor between VDD and VL2
Capacitor between VDD and VL3
Capacitor between VDD and VS1
1: When the heavy load protection mode is set by software and the SVD circuit is turned off. Cannot be operated when the CR
oscillation circuit is used.
2: The voltage which can be displayed on the LCD panel will differ according to the characteristics of the LCD panel.
3: When there is no software control during CR oscillation or crystal oscillation.
4