E0C6S32
■ ELECTRICAL CHARACTERISTICS
● Absolute Maximum Ratings
E0C6S32/6SA32/6SB32
(VDD=0V)
Rating
Supply voltage
Symbol
VSS
Value
-5.5 to 0.5
Unit
V
Input voltage (1)
Input voltage (2)
Permissible total output current *1 ΣIVSS
Operating temperature
Storage temperature
Soldering temperature / Time
Permissible dissipation *2
VI
VIOSC
VSS - 0.3 to 0.5
VS1 - 0.3 to 0.5
10
-20 to 70
-65 to 150
V
V
mA
°C
°C
–
Topr
Tstg
Tsol
PD
260°C, 10sec (lead section)
250
mW
1: The permissible total output current is the sum total of the current (average current) that simultaneously flows from the output pins (or is draw in).
2: In case of plastic package (QFP5-80pin, QFP14-80pin).
E0C6SL32
(VDD=0V)
Rating
Symbol
VSS
Value
-2.0 to 0.5
Unit
V
Supply voltage
Input voltage (1)
Input voltage (2)
Permissible total output current *1 ΣIVSS
Operating temperature
Storage temperature
VI
VIOSC
VSS - 0.3 to 0.5
VS1 - 0.3 to 0.5
10
-20 to 70
-65 to 150
V
V
mA
°C
°C
–
Topr
Tstg
Tsol
PD
Soldering temperature / Time
Permissible dissipation *2
260°C, 10sec (lead section)
250
mW
1: The permissible total output current is the sum total of the current (average current) that simultaneously flows from the output pins (or is draw in).
2: In case of plastic package (QFP5-80pin, QFP14-80pin).
● Recommended Operating Conditions
E0C6S32
(Ta=-20 to 70°C)
Condition
Supply voltage
Oscillation frequency
Symbol
Remark
Remark
Min.
-3.6
–
Typ.
-3.0
32.768
Max.
-1.8
–
Unit
V
kHz
V
SS
VDD=0V
f
OSC1
E0C6SL32
Condition
Supply voltage
(Ta=-20 to 70°C)
Symbol
VSS
Min.
-1.8
-1.8
-1.8
–
Typ.
-1.5
-1.5
-1.5
32.768
Max.
-1.1
-0.9 *2
-1.2
–
Unit
V
V
V
kHz
VDD=0V
VDD=0V, With software control *1
VDD=0V, When the analog comparator is used
Oscillation frequency
fOSC1
1: When switching to heavy load protection mode. Note, however, that the ON time for BLS in the heavy load protection must be limited
to 10 msec per second of operation time.
2: The possibility of LCD panel display differs depending on the characteristics of the LCD panel.
E0C6SB32
(Ta=-20 to 70°C)
Condition
Supply voltage
Symbol
VSS
Remark
Min.
-3.6
-3.6
-3.6
–
Typ.
-1.5
-1.5
-1.5
32.768
Max.
-1.1
-0.9 *2
-1.2
–
Unit
V
V
V
kHz
VDD=0V
VDD=0V, With software control *1
VDD=0V, When the analog comparator is used
Oscillation frequency
fOSC1
1: When switching to heavy load protection mode. Note, however, that the ON time for BLS in the heavy load protection must be limited
to 10 msec per second of operation time.
2: The possibility of LCD panel display differs depending on the characteristics of the LCD panel.
E0C6SA32
(Ta=-20 to 70°C)
Condition
Supply voltage
Oscillation frequency (1)
Oscillation frequency (2)
Symbol
VSS
fOSC1
Remark
Min.
-3.6
–
Typ.
-3.0
32.768
1000
Max.
-1.8
–
Unit
V
kHz
kHz
VDD=0V
fOSC3 duty 50±5%
300
1300
4