SS1636
Unipolar Hall Switch-High sensitivity
General Electrical Specifications
DC Operating Parameters TA = 25°C, VDD= 2.5V to 5.5V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Typ
Max Units
Supply Voltage
Supply Current
Output Current
Saturation Voltage
Awake mode time
Sleep mode time
VDD
IDD
Operating
B < BRP
2.5
3
5.5
V
μA
mA
V
45
1.0
0.4
20
IOUT
VSAT
TAW
TSL
IOUT=1mA
Operating
Operating
µs
600
µs
Magnetic Specifications
Package
Parameter
Symbol
Test Conditions
Min
Typ
Max Units
Operating Point
Release Point
Hysteresis
BOP
30
10
60
50
100
80
G
G
G
G
G
G
BRP
UA
Ta=25°C,Vdd=12V DC
BHYST
BOP
30
Operating Point
Release Point
Hysteresis
-100
-80
-60
-50
30
-30
-10
BRP
ST
Ta=25°C,Vdd=12V DC
BHYST
Output Behavior versus Magnetic Pole
DC Operating Parameters TA = -40°C to 150°C, VDD = 2.5V to 5.5V (unless otherwise specified)
Test Conditions (UA) Test Conditions (ST)
OUT
B < BRP
B > BOP
B > BRP
B < BOP
High
Low
The SOT-23 device is reversed from the UA package. The SOT-23 output transistor will be turned on(drops low) in the
presence of a sufficiently strong North pole magnetic field applied to the marked face.
3
V3.10 Nov 1, 2013