Operation
The end user must apply a magnetic field planar with the IC package in the direction of sensitivity of
the part (the cross-axis direction). As the applied magnetic field changes intensity and polarity, the
digital output will turn on and off. The part is configured for pull down operation when in the “ON”
state. An external pull-up resistor is required.
Functional Block Diagram and Pinout
ADV001-00E
Vcc
N/C
Out
N/C
Output
GMR
Sensor
N/C
N/C
N/C
Direction of Sensitivity
(“South”)
Ground
Package
MSOP8
TDFN6
Pinout
VCC
Ground
Out
(ADV001-00E) (ADV001-10E)
Pin 1
Pin 5
Pin 8
Pin 1
Pin 4
Pin 6
- 2 -
www.rhopointcomponents.com