FM3135 Integrated RTC/Alarm/FRAM & Embedded Crystal  
26  
27  
28  
29  
30  
31  
512.0567  
512.0589  
512.0611  
512.0633  
512.0656  
512.0678  
512.0589  
512.0611  
512.0633  
512.0656  
512.0678  
512.0700  
110.68  
115.02  
119.36  
123.70  
128.04  
132.38  
115.01  
119.35  
123.69  
128.03  
132.37  
136.71  
011010  
011011  
011100  
011101  
011110  
011111  
Alarm  
Function of the ACS Pin  
The alarm function compares user-programmed  
alarm values to the corresponding RTC time/date  
values. When a match occurs, an alarm event occurs.  
The alarm event sets an internal flag AF (register  
00h, bit 6) and drives the ACS pin low, if the  
appropriate control bits are set in registers 00h and  
0Eh. See Table 3. The alarm condition on the ACS  
pin and the AF bit are cleared by reading register  
00h.  
The ACS pin is a multifunction pin. The alarm,  
calibration, and square wave functions all share this  
output. There are two ways a user can detect an alarm  
event, by reading the AF flag or by monitoring the  
ACS pin. An interrupt pin on the host processor may  
be used to detect an alarm event. The AF flag in the  
register 00h (bit 6) will indicate that a time/date  
match has occurred. When a match occurs, the AF  
bit will be set to ‘1’ and the ACS pin will drive low.  
The flag and ACS pin will remain in this state until  
the RTC/Alarm Control register is read which clears  
the AF bit.  
The alarm operates under VDD or VBAK power. If the  
system controller is being used to detect an alarm  
while the FM3135 is powered on VBAK only, the ACS  
pin may cause extra IBAK current when the alarm is  
activated. To avoid battery drain, the ACS pin can be  
tri-stated by reading the AF flag, located in the  
RTC/Alarm Control register 00h.  
Table 3 that shows the relationship between register  
control settings and the function of the ACS pin.  
Table 3. Control Bit Settings for ACS Pin  
There are five alarm match fields. They are Month,  
Date, Hours, Minutes, and Seconds. Each of these  
fields also has a Match bit that is used to determine if  
the field is used in the alarm match logic. Setting the  
Match bit to ‘0’ indicates that the corresponding field  
will be used in the match process.  
State of Register Bit  
Function of  
ACS pin  
CAL AEN AL/SW  
0
0
1
0
1
X
X
0
1
/Alarm  
Sq Wave out  
512 Hz out  
Hi-Z  
0
X
1
Depending on the Match bits, the alarm can occur as  
specifically as one particular second on one day of  
the month, or as frequently as once per second  
continuously. The MSB of each Alarm register is a  
Match bit. Examples of the Match bit settings are  
shown in Table 4. Alarm Match Bit Examples.  
Selecting none of the match bits (all ‘1’s) indicates  
that no match is required. The alarm occurs every  
second. Setting the match select bit for seconds to ‘0’  
causes the logic to match the seconds alarm value to  
the current time of day. Since a match will occur for  
only one value per minute, the alarm occurs once per  
minute. Likewise setting the seconds and minutes  
match select bits causes an exact match of these  
values. Thus, an alarm will occur once per hour.  
Setting seconds, minutes, and hours causes a match  
once per day. See Table 4 for other alarm setting  
examples.  