FM24W256 - 256Kb Wide Voltage I2C F-RAM  
Stop  
Start  
S
Address & Data  
Address MSB  
By Master  
Slave Address  
0
A
X
A
Address LSB  
A
Data Byte  
A
P
By FM24W256  
Acknowledge  
Figure 5. Single Byte Write  
Start  
Stop  
P
Address & Data  
Address MSB  
By Master  
S
Slave Address  
0
A
X
A
Address LSB  
A
Data Byte  
A
Data Byte  
A
By FM24W256  
Acknowledge  
Figure 6. Multiple Byte Write  
Read Operation  
There are four ways to properly terminate a read  
operation. Failing to properly terminate the read will  
There are two basic types of read operations. They  
are current address read and selective address read. In  
a current address read, the FM24W256 uses the  
internal address latch to supply the address. In a  
selective read, the user performs a procedure to set  
the address to a specific value.  
most likely create  
a bus contention as the  
FM24W256 attempts to read out additional data onto  
the bus. The four valid methods are:  
1. The bus master issues a no-acknowledge in the  
9th clock cycle and a stop in the 10th clock cycle.  
This is illustrated in the diagrams below. This is  
preferred.  
Current Address & Sequential Read  
As mentioned above the FM24W256 uses an internal  
latch to supply the address for a read operation. A  
current address read uses the existing value in the  
address latch as a starting place for the read  
operation. The system reads from the address  
immediately following that of the last operation.  
2. The bus master issues a no-acknowledge in the  
9th clock cycle and a start in the 10th.  
3. The bus master issues a stop in the 9th clock  
cycle.  
4. The bus master issues a start in the 9th clock  
cycle.  
To perform a current address read, the bus master  
supplies a slave address with the LSB set to 1. This  
indicates that a read operation is requested. After  
receiving the complete slave address, the FM24W256  
will begin shifting out data from the current address  
on the next clock. The current address is the value  
held in the internal address latch.  
If the internal address reaches 7FFFh, it will wrap  
around to 0000h on the next read cycle. Figures 7 and  
8 below show the proper operation for current  
address reads.  
Selective (Random) Read  
There is a simple technique that allows a user to  
select a random address location as the starting point  
for a read operation. This involves using the first  
three bytes of a write operation to set the internal  
address followed by subsequent read operations.  
Beginning with the current address, the bus master  
can read any number of bytes. Thus, a sequential read  
is simply a current address read with multiple byte  
transfers. After each byte the internal address counter  
will be incremented.  
To perform a selective read, the bus master sends out  
the slave address with the LSB set to 0. This specifies  
a write operation. According to the write protocol,  
the bus master then sends the address bytes that are  
Each time the bus master acknowledges a byte,  
this indicates that the FM24W256 should read  
out the next sequential byte.  
Rev. 1.3  