欢迎访问ic37.com |
会员登录 免费注册
发布采购

FM24W256-GTR 参数 Datasheet PDF下载

FM24W256-GTR图片预览
型号: FM24W256-GTR
PDF下载: 下载PDF文件 查看货源
内容描述: 256KB宽电压串行F-RAM [256Kb Wide Voltage Serial F-RAM]
分类和应用: 存储内存集成电路光电二极管
文件页数/大小: 13 页 / 229 K
品牌: RAMTRON [ RAMTRON INTERNATIONAL CORPORATION ]
 浏览型号FM24W256-GTR的Datasheet PDF文件第1页浏览型号FM24W256-GTR的Datasheet PDF文件第2页浏览型号FM24W256-GTR的Datasheet PDF文件第3页浏览型号FM24W256-GTR的Datasheet PDF文件第5页浏览型号FM24W256-GTR的Datasheet PDF文件第6页浏览型号FM24W256-GTR的Datasheet PDF文件第7页浏览型号FM24W256-GTR的Datasheet PDF文件第8页浏览型号FM24W256-GTR的Datasheet PDF文件第9页  
FM24W256 - 256Kb Wide Voltage I2C F-RAM  
SCL  
SDA  
7
6
0
Stop  
Start  
Data bits  
(Transmitter)  
Data bit Acknowledge  
(Transmitter) (Receiver)  
(Master) (Master)  
Figure 3. Data Transfer Protocol  
Stop Condition  
Second and most common, the receiver does not  
acknowledge to deliberately end an operation. For  
example, during a read operation, the FM24W256  
will continue to place data onto the bus as long as  
the receiver sends acknowledges (and clocks). When  
a read operation is complete and no more data is  
needed, the receiver must not acknowledge the last  
byte. If the receiver acknowledges the last byte, this  
will cause the FM24W256 to attempt to drive the  
bus on the next clock while the master is sending a  
new command such as stop.  
A stop condition is indicated when the bus master  
drives SDA from low to high while the SCL signal is  
high. All operations using the FM24W256 should  
end with a stop condition. If an operation is in  
progress when a stop is asserted, the operation will be  
aborted. The master must have control of SDA (not a  
memory read) in order to assert a stop condition.  
Start Condition  
A start condition is indicated when the bus master  
drives SDA from high to low while the SCL signal is  
high. All commands should be preceded by a start  
condition. An operation in progress can be aborted by  
asserting a start condition at any time. Aborting an  
operation using the start condition will ready the  
FM24W256 for a new operation.  
Slave Address  
The first byte that the FM24W256 expects after a  
start condition is the slave address. As shown in  
Figure 4, the slave address contains the device type,  
the device select address bits, and a bit that specifies  
if the transaction is a read or a write.  
If during operation the power supply drops below the  
specified VDD minimum, the system should issue a  
start condition prior to performing another operation.  
Bits 7-4 are the device type and should be set to  
1010b for the FM24W256. These bits allow other  
types of function types to reside on the 2-wire bus  
within an identical address range. Bits 3-1 are the  
address select bits. They must match the  
corresponding value on the external address pins to  
select the device. Up to eight FM24W256s can  
reside on the same two-wire bus by assigning a  
different address to each. Bit 0 is the read/write bit.  
R/W=1 indicates a read operation and R/W=0  
indicates a write operation.  
Data/Address Transfer  
All data transfers (including addresses) take place  
while the SCL signal is high. Except under the two  
conditions described above, the SDA signal should  
not change while SCL is high.  
Acknowledge  
The acknowledge takes place after the 8th data bit has  
been transferred in any transaction. During this state  
the transmitter should release the SDA bus to allow  
the receiver to drive it. The receiver drives the SDA  
signal low to acknowledge receipt of the byte. If the  
receiver does not drive SDA low, the condition is a  
no-acknowledge and the operation is aborted.  
The receiver would fail to acknowledge for two  
distinct reasons. First is that a byte transfer fails. In  
this case, the no-acknowledge ceases the current  
operation so that the part can be addressed again.  
This allows the last byte to be recovered in the event  
of a communication error.  
Rev. 1.3  
July 2011  
Page 4 of 13