FM24C04C  
Figure 3. Data Transfer Protocol  
byte to be recovered in the event of a communication  
error. Second and most common, the receiver does  
not acknowledge the data to deliberately end an  
operation. For example, during a read operation, the  
FM24C04C will continue to place data onto the bus  
as long as the receiver sends acknowledges (and  
clocks). When a read operation is complete and no  
more data is needed, the receiver must not  
acknowledge the last byte. If the receiver  
acknowledges the last byte, this will cause the  
FM24C04C to attempt to drive the bus on the next  
clock while the master is sending a new command  
such as a Stop command.  
Stop Condition  
A Stop condition is indicated when the bus master  
drives SDA from low to high while the SCL signal is  
high. All operations must end with a Stop condition. If  
an operation is pending when a stop is asserted, the  
operation will be aborted. The master must have  
control of SDA (not a memory read) in order to assert  
a Stop condition.  
Start Condition  
A Start condition is indicated when the bus master  
drives SDA from high to low while the SCL signal is  
high. All read and write transactions begin with a Start  
condition. An operation in progress can be aborted by  
asserting a Start condition at any time. Aborting an  
operation using the Start condition will ready the  
FM24C04C for a new operation.  
Slave Address  
The first byte that the FM24C04C expects after a  
start condition is the slave address. As shown in  
Figure 4, the slave address contains the device type,  
the device select, the page of memory to be  
accessed, and a bit that specifies if the transaction is  
a read or a write.  
If during operation the power supply drops below the  
specified VDD minimum, the system should issue a  
Start condition prior to performing another operation.  
Bits 7-4 are the device type and should be set to  
1010b for the FM24C04C. The device type allows  
other types of functions to reside on the 2-wire bus  
within an identical address range. Bits 3-2 are the  
device address. If bit 3 matches the A2 pin and bit 2  
matches the A1 pin the device will be selected. Bit 1  
is the page select. It specifies the 256-byte block of  
memory that is targeted for the current operation. Bit  
0 is the read/write bit. A 0 indicates a write  
operation.  
Data/Address Transfer  
All data transfers (including addresses) take place  
while the SCL signal is high. Except under the two  
conditions described above, the SDA signal should not  
change while SCL is high.  
Acknowledge  
The Acknowledge takes place after the 8th data bit has  
been transferred in any transaction. During this state  
the transmitter should release the SDA bus to allow the  
receiver to drive it. The receiver drives the SDA signal  
low to acknowledge receipt of the byte. If the receiver  
does not drive SDA low, the condition is a No-  
Acknowledge and the operation is aborted.  
Word Address  
After the FM24C04C (as receiver) acknowledges the  
slave ID, the master will place the word address on  
the bus for a write operation. The word address is  
the lower 8-bits of the address to be combined with  
the 1-bit page select to specify exactly the byte to be  
written. The complete 9-bit address is latched  
internally.  
The receiver could fail to acknowledge for two distinct  
reasons. First, if a byte transfer fails, the No-  
Acknowledge ends the current operation so that the  
device can be addressed again. This allows the last  
Rev. 1.1  
June 2011  
Page 4 of 12