P4C1024
MAXIMUM RATINGS(1)
Symbol
Parameter
Value
Unit
Symbol
Parameter
Value
Unit
VCC
Power Supply Pin with
Respect to GND
–0.5 to +7
V
TBIAS
Temperature Under
Bias
–55 to +125
°C
Terminal Voltage with
Respect to GND
(up to 7.0V)
–0.5 to
TSTG
PT
IOUT
Storage Temperature
Power Dissipation
DC Output Current
–65 to +150
°C
W
mA
VTERM
TA
VCC +0.5
V
1.0
50
Operating Temperature –55 to +125 °C
CAPACITANCES(4)
RECOMMENDED OPERATING
VCC = 5.0V, TA = 25°C, f = 1.0MHz
TEMPERATURE AND SUPPLY VOLTAGE
Ambient
Grade(2)
GND
Symbol
Parameter
Conditions Typ. Unit
VCC
Temperature
Military
Industrial
Commercial
5.0V ± 10%
5.0V ± 10%
5.0V ± 10%
CIN
COUT
–55°C to +125°C
–40°C to +85°C
0°C to +70°C
0V
0V
0V
VIN = 0V
VOUT = 0V
pF
pF
Input Capacitance
Output Capacitance
8
10
DC ELECTRICAL CHARACTERISTICS
Over recommended operating temperature and supply voltage(2)
P4C1024
P4C1024L
Symbol
Parameter
Test Conditions
Unit
Min
Max
Min
Max
2.2
–0.5(3)
VCC +0.5
2.2
–0.5(3)
VCC +0.5
VIH
VIL
Input High Voltage
Input Low Voltage
V
V
V
0.8
0.8
VCC –0.2 VCC +0.5 VCC –0.2 VCC +0.5
–0.5(3)
VHC
VLC
CMOS Input High Voltage
CMOS Input Low Voltage
0.2
–1.2
–0.5(3)
2.4
0.2
–1.2
V
V
VCD
VOL
VCC = Min., IIN = –18 mA
IOL = +8 mA, VCC = Min.
Input Clamp Diode Voltage
Output Low Voltage
V
0.4
0.4
(TTL Load)
Output High Voltage
(TTL Load)
VOH
ILI
IOH = –4 mA, VCC = Min.
VCC = Max.
V
2.4
Mil.
–10
–5
+10
+5
–5
+5
Input Leakage Current
µA
n/a
n/a
VIN = GND to VCC
VCC = Max., CE = VIH,
Ind./Com’l.
Mil.
–10
–5
+10
+5
–5
+5
µA
ILO
Output Leakage Current
n/a
n/a
VOUT = GND to VCC Ind./Com’l.
___
___
___
___
mA
CE1 ≥ VIH or
CE2 ≤VIL,
Mil.
35
30
25
Ind./Com’l.
n/a
Standby Power Supply
ISB
VCC= Max,
Current (TTL Input Levels)
f = Max., Outputs Open
___
___
___
___
25
20
2
mA
CE1 ≥ VHC or
Mil.
Ind./Com’l.
Standby Power Supply
Current
n/a
CE2 ≤VLC,
ISB1
VCC= Max,
(CMOS Input Levels)
f = 0, Outputs Open
VIN ≤ VLC or VIN ≥ VHC
Notes:
periods may affect reliability.
1. Stresses greater than those listed under MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification
is not implied. Exposure to MAXIMUM rating conditions for extended
2. Extended temperature operation guaranteed with 400 linear feet per
minute of air flow.
3. Transient inputs with VIL and IIL not more negative than –3.0V and
–100mA, respectively, are permissible for pulse widths up to 20ns.
4. This parameter is sampled and not 100% tested.
Document # SRAM124 REV A