INT100
Conditions
(Unless Otherwise Specified)
VDDH = VDD = 15 V
Parameter
Symbol
Min
Typ
Max
Units
HS RTN = LS RTN = COM = 0 V
TA = -40 to 85°C
LEVEL SHIFT
VDDH = HS OUT = HS RTN
Breakdown
Voltage
BVDSS
V
800
IHS RTN = 100 µA
Leakage
Current
IHS RTN)
µA
pF
VDDH = HS OUT = HS RTN = 500 V
VDDH = HS OUT = HS RTN = 500 V
0.2
20
30
Interface
Capacitance
SYSTEM RESPONSE
Deadtime (Low
DtP+
DtP-
ns
ns
See Figure 7
See Figure 7
0
0
450
300
Off to High On)
Deadtime (High
Off to Low On)
UNDERVOLTAGE LOCKOUT
VDD(UV)
VDDH(UV)
Input UV
Trip-off Voltage
V
8.5
9.0
10
Input UV
Hysteresis
mV
175
350
SUPPLY
Supply
Current
IDD, IDDH
mA
V
See Note 2
1.5
3.0
16
Supply
Voltage
VDD, VDDH
10
NOTES:
1. Applying a short circuit to the LS OUT or HS OUT pin for more than 500 µs will exceed the thermal rating of the
package, resulting in destruction of the part.
2. VDD, VDDH supply must have less than 30Ω output impedance.
C
6/96
7