InnoSwitch-CH  
Over-Temperature Protection  
The thermal shutdown circuitry senses the primary die temperature.  
This threshold is set to 142 °C with 75 °C hysteresis. When the die  
temperature rises above this threshold the power MOSFET is disabled  
and remains disabled until the die temperature falls by 75 °C, at which  
point it is re-enabled. A large hysteresis of 75 °C is provided to  
prevent over-heating of the PC board due to continuous fault condition.  
ꢖꢋ ꢖꢐꢓꢧꢍꢐꢟ ꢜꢔꢓꢎ  
ꢊꢋ ꢊeꢗꢉꢕꢑꢍꢐꢟ ꢜꢔꢓꢎ  
ꢊꢂꢍꢐꢂ  
ꢖꢋ ꢖꢉꢏeꢐeꢑ ꢦꢎꢞ ꢊꢏꢓꢂꢗꢔꢓꢕꢙ  
ꢊꢋ ꢖꢉꢏeꢐꢓꢕꢙ ꢦꢎ  
Current Limit Operation  
The current limit circuit senses the current in the power MOSFET.  
When this current exceeds the internal threshold (ILIMIT), the power  
MOSFET is turned off for the remainder of that switch cycle. The  
current limit state-machine reduces the current limit threshold by  
discrete amounts under medium and light loads.  
ꢖꢋ ꢃꢒꢂꢉꢣReꢁꢂꢍꢐꢂ  
ꢊꢋ ꢖꢉꢏeꢐꢓꢕꢙ ꢦꢎ  
ꢃRꢄꢅꢆꢆꢇ  
ꢊꢋ ꢌꢍꢁ ꢎꢉꢏeꢐeꢑ  
ꢒꢎ ꢏꢓꢂꢔꢓꢕ ꢂꢃR  
ꢈꢉ  
ꢈꢉ  
ꢈꢉ  
The leading edge blanking circuit inhibits the current limit comparator  
for a short time (tLEB) after the power MOSFET is turned-on. This  
leading edge blanking time has been set so that current spikes  
caused by capacitance and secondary-side rectifier reverse recovery  
time will not cause premature termination of the switching pulse.  
Each switching cycle is terminated when the Drain current of the  
primary power MOSFET reaches the current limit of the device.  
ꢖꢋ ꢢꢉeꢁ ꢂꢉ ꢃꢒꢂꢉꢣReꢁꢂꢍꢐꢂ ꢅꢤꢤ  
ꢊꢋ ꢥꢟꢎꢍꢁꢁ ꢠꢓꢁꢗꢔꢍꢐꢙꢓꢕꢙ  
ꢀeꢁ  
ꢃR  
ꢖꢋ ꢊꢏꢓꢂꢗꢔꢓꢕꢙ  
ꢊꢋ ꢊeꢕꢑꢁ ꢌꢍꢕꢑꢁꢔꢍꢘꢓꢕꢙ ꢖꢒꢚꢁeꢁ  
Auto-Restart  
In the event of a fault condition such as output overload, output  
short-circuit or external component/pin fault, the InnoSwitch-CH  
enters into auto-restart (AR) operation. In auto-restart operation the  
power MOSFET switching is disabled for tAR(OFF). There are 2 ways to  
enter auto-restart after the secondary has taken control:  
ꢖꢋ ꢌꢍꢁ Reꢗeꢓveꢑ  
ꢌꢍꢕꢑꢁꢔꢍꢘꢓꢕꢙ  
ꢖꢒꢚꢁeꢁ  
ꢖꢋ ꢜꢉꢕꢂꢓꢕꢒꢉꢒꢁ ꢊꢏꢓꢂꢗꢔꢓꢕꢙ  
ꢊꢋ ꢠꢉeꢁꢕꢡꢂ ꢘe ꢜꢉꢕꢂꢐꢉꢚ  
1. Continuous switching requests from the secondary for time period  
exceeding tAR.  
ꢀeꢁ  
2. No requests for switching cycles from the secondary for a time  
ꢖꢋ ꢊꢂꢉꢎꢁ ꢊꢏꢓꢂꢗꢔꢓꢕꢙꢞ ꢌꢍꢕꢑꢁ  
ꢅveꢐ ꢜꢉꢕꢂꢐꢉꢚ ꢂꢉ ꢊeꢗꢉꢕꢑꢍꢐꢟ  
period exceeding tAR(SK)  
.
The first condition corresponds to a condition wherein the secondary  
controller makes continuous cycle requests without a skipped-cycle  
for more than tAR time period. The second method was included to  
ensure that if communication is lost, the primary tries to restart again.  
Although this should never be the case in normal operation, this can  
be useful in the case of system ESD events for example where a loss  
of communication due to noise disturbing the secondary controller, is  
resolved when the primary restarts after an auto-restart off time.  
ꢊꢋ ꢌꢍꢁ ꢘeꢕ  
ꢜꢉꢕꢂꢐꢉꢚꢝ  
ꢖꢋ ꢈꢉꢂ ꢊꢏꢓꢂꢗꢔꢓꢕꢙ  
ꢊꢋ ꢠꢉeꢁꢕꢡꢂ ꢘe ꢜꢉꢕꢂꢐꢉꢚ  
ꢀeꢁ  
The auto-restart alternately enables and disables the switching of the  
power MOSFET until the fault is removed. The auto-restart counter is  
gated by the switch oscillator in SOA mode the auto-restart off timer  
may appear to be longer.  
ꢨꢕꢑ ꢉꢤ ꢌꢍꢕꢑꢁꢔꢍꢘꢓꢕꢙꢞ  
ꢊeꢗꢉꢕꢑꢍꢐꢟ ꢜꢉꢕꢂꢐꢉꢚ ꢩꢉꢑe  
ꢖꢪꢣ7ꢫ1ꢬꢣ110ꢫ1ꢫ  
The auto-restart counter is reset once the primary PRIMARY BYPASS  
Figure 6. Primary – Secondary Handshake Flowchart.  
pin falls below the undervoltage threshold VBPP-VBPP(HYS)  
.
Safe-Operating-Area (SOA) Protection  
onwards the secondary is in control of demanding switching cycles  
when required.  
In the event there are two consecutive cycles where the primary  
power MOSFET switch current reaches current limit (ILIM) within the  
blanking (tLEB) and current limit (tILD) delay time, the controller will  
skip approximately 2.5 cycles or ~25 msec. This provides sufficient  
time for reset of the transformer without sacrificing start-up time into  
large capacitive load. Auto-restart timing is increased when the  
device is operating in SOA-mode.  
The handshake flowchart is shown in Figure 6.  
In the event the primary stops switching or does not respond to cycle  
requests from the secondary during normal operation when the  
secondary has control, the handshake protocol is imitated to ensure  
that the secondary is ready to assume control once the primary  
begins switching again. This protocol for an additional handshake is  
also invoked in the event the secondary detects that the primary is  
providing more cycles than were requested.  
Primary-Secondary Handshake Protocol  
At start-up, the primary initially switches without any feedback  
information (this is very similar to the operation of a standard  
TOPSwitch™, TinySwitch™ or LinkSwitch™ controllers). If no  
feedback signals are received during the auto-restart on-time, the  
primary goes into auto-restart and repeats. However under normal  
conditions, the secondary chip will power-up through the FORWARD  
pin or directly from VOUT and then take over control. From then  
The most likely event that could require an additional handshake is  
when the primary stops switching resulting from a momentary line  
drop-out or brown-out event. When the primary resumes operation,  
it will default into a start-up condition and attempt to detect hand-  
shake pulses from the secondary.  
4
Rev. J 10/17  
www.power.com