VCO coil adjustment methods
1. Input SG2 (fo=58.75MHz, 90dBµ CW) into VIF IN.
2. And adjust the coil until the voltage of AFT output reaches about
Vcc/2=2.5V.
FM DET coil adjustment methods
1. The first thing, adjust the VCO coil.
2. Input SG13 (fo=54.25MHz, 95dBµ CW) into SIF IN.
3. Change the switch of SW13 and SW15 to 2 position.
4. Change to FM RADIO mode (V10=0V).
5. Adjust the DC voltage of AFT OUT to Vcc/2 and SIF det OUT to Low (under 1V).