欢迎访问ic37.com |
会员登录 免费注册
发布采购

EUP3484SDIR1 参数 Datasheet PDF下载

EUP3484SDIR1图片预览
型号: EUP3484SDIR1
PDF下载: 下载PDF文件 查看货源
内容描述: [3A, 24V, 340KHz Synchronous Step-Down Converter]
分类和应用:
文件页数/大小: 11 页 / 783 K
品牌: EUTECH [ EUTECH MICROELECTRONICS INC ]
 浏览型号EUP3484SDIR1的Datasheet PDF文件第1页浏览型号EUP3484SDIR1的Datasheet PDF文件第3页浏览型号EUP3484SDIR1的Datasheet PDF文件第4页浏览型号EUP3484SDIR1的Datasheet PDF文件第5页浏览型号EUP3484SDIR1的Datasheet PDF文件第6页浏览型号EUP3484SDIR1的Datasheet PDF文件第7页浏览型号EUP3484SDIR1的Datasheet PDF文件第8页浏览型号EUP3484SDIR1的Datasheet PDF文件第9页  
EUP3484S  
Pin Configurations  
Package Type  
Pin Configurations  
SOP-8 (EP)  
Pin Description  
PIN  
PIN NAME  
DESCRIPTION  
High-Side Gate Drive Boost Input. BS supplies the drive for the high-side N-Channel  
DMOS switch. Connect a 0.01µF or greater capacitor from SW to BS to power the  
high side switch.  
Input Supply Pin. IN supplies the power to the IC, as well as the step-down converter  
switches. Drive IN with a 4.5V to 24V power source. Bypass IN to GND with a  
suitably large capacitor to minimize input ripple to the IC. See Input Capacitor  
Section of the applications notes.  
1
BS  
IN  
2
3
Power Switching Output. Connect the output LC filter from SW to the output load.  
SW  
Ground. GND pin should be connected to the exposed thermal pad for proper  
operation. This power thermal pad should be connected to PCB ground plane using  
multiple vias for good thermal performance.  
4
GND  
9 (Exposed Pad)  
Output Feedback Input. FB senses the output voltage and regulates it. Drive FB with a  
resistive voltage divider connected to it from the output voltage. The feedback threshold  
is 0.925V. See Setting the Output Voltage.  
Loop compensation Input. Connect a series RC network from COMP to GND to  
compensate the regulation control loop. See Compensation.  
Enable Input. EN is a logic input that controls the regulator on or off. Drive EN high to  
turn on the regulator; low to turn it off. Don’t leave EN pin floating. Directly connect  
EN to IN (or through a resistance) for automatic startup.  
Soft-Start Control Input. Connect an external capacitor to program the soft-start. If  
unused, leave it open, which means internal soft-start function.  
5
6
7
8
FB  
COMP  
EN  
SS  
DS3484S Ver1.2 May 2012  
2