PSKEBC4/D0(0B0eCttysWeur)ies Direct ConvertersEZHEWNG 2009-2-18
Input 36-75 V, Output up to 60 A / 144 W
H
© Ericsson AB
1 V/50 A Typical Characteristics
PKB 4518NC PI
Start-up
Shut-down
Start-up enabled by connecting VI at:
Tp1 = +25°C, VI = 53 V,
IO = 50 A resistive load.
Top trace: output voltage (0.5 V/div.).
Bottom trace: input voltage (50 V/div.).
Time scale: (5 ms/div.).
Shut-down enabled by disconnecting VI at:
Tp1 = +25°C, VI = 53 V,
IO = 50 A resistive load.
Top trace: output voltage (0.5 V/div.).
Bottom trace: input voltage (50 V/div.).
Time scale: (0.1 ms/div.).
Output Ripple & Noise
Output Load Transient Response
Output voltage ripple at:
Tp1 = +25°C, VI = 53 V,
Trace: output voltage (20mV/div.).
Time scale: (2 µs/div.).
Output voltage response to load current step- Top trace: output voltage (50mV/div.).
change (25-37.5-25 A) at:
Tp1 =+25°C, VI = 53 V.
Bottom trace: load current (10 A/div.).
Time scale: (0.5 ms/div.).
I
O = 50 A resistive load.
Output Voltage Adjust (see operating information)
Passive adjust
The resistor value for an adjusted output voltage is calculated by
using the following equations:
Output Voltage Adjust Downwards, Decrease:
511
Radj
10.22
k
%
Output Voltage Adjust Upwards, Increase:
5.111.0
100 %
511
Radj
10.22
Example: Decrease 2% =>Vout = 0.98 Vdc
k
0.6215%
%
511
10.22
k = 245 k
2
Example: Increase 4% =>Vout = 1.04 Vdc
5.111.0
100 4
0.6215 4
511
4
10.22
k = 78.9 k