欢迎访问ic37.com |
会员登录 免费注册
发布采购

PKB4518NC 参数 Datasheet PDF下载

PKB4518NC图片预览
型号: PKB4518NC
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module,]
分类和应用:
文件页数/大小: 43 页 / 893 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号PKB4518NC的Datasheet PDF文件第1页浏览型号PKB4518NC的Datasheet PDF文件第2页浏览型号PKB4518NC的Datasheet PDF文件第4页浏览型号PKB4518NC的Datasheet PDF文件第5页浏览型号PKB4518NC的Datasheet PDF文件第6页浏览型号PKB4518NC的Datasheet PDF文件第7页浏览型号PKB4518NC的Datasheet PDF文件第8页浏览型号PKB4518NC的Datasheet PDF文件第9页  
E
3
Technical Specification  
EN/LZT 146 377 R4D September 2013  
PKB4000C series Direct Converters  
Input 36-75 V, Output up to 60 A / 144 W  
© Ericsson AB  
injury to a person’s health or life).  
Isolated DC/DC converters & Power interface modules  
© Ericsson AB 2013  
The product may provide basic or functional insulation  
between input and output according to IEC/EN/UL 60950-1  
(see Safety Certificate), different conditions shall be met if  
the output of a basic or a functional insulated product shall  
be considered as safety extra low voltage (SELV).  
The information and specifications in this technical  
specification is believed to be correct at the time of  
publication. However, no liability is accepted for  
inaccuracies, printing errors or for any consequences  
thereof. Ericsson AB reserves the right to change the  
contents of this technical specification at any time without  
prior notice.  
For basic insulated products (see Safety Certificate) the  
output is considered as safety extra low voltage (SELV) if  
one of the following conditions is met:  
Safety Specification  
General information  
The input source provides supplementary or double or  
reinforced insulation from the AC mains according to  
IEC/EN/UL 60950-1.  
The input source provides functional or basic insulation  
from the AC mains and the product’s output is reliably  
connected to protective earth according to  
IEC/EN/UL 60950-1.  
Ericsson Power Modules DC/DC converters and DC/DC  
regulators are designed in accordance with the safety  
standards IEC 60950-1, EN 60950-1 and UL 60950-1  
Safety of Information Technology Equipment.  
IEC/EN/UL 60950-1 contains requirements to prevent injury  
or damage due to the following hazards:  
For functional insulated products (see Safety Certificate)  
the output is considered as safety extra low voltage (SELV)  
if one of the following conditions is met:  
Electrical shock  
Energy hazards  
Fire  
Mechanical and heat hazards  
Radiation hazards  
Chemical hazards  
The input source provides double or reinforced  
insulation from the AC mains according to  
IEC/EN/UL 60950-1.  
The input source provides basic or supplementary  
insulation from the AC mains and the product’s output is  
reliably connected to protective earth according to  
IEC/EN/UL 60950-1.  
The input source is reliably connected to protective  
earth and provides basic or supplementary insulation  
according to IEC/EN/UL 60950-1 and the maximum  
input source voltage is 60 Vdc.  
On-board DC/DC converters and DC/DC regulators are  
defined as component power supplies. As components  
they cannot fully comply with the provisions of any safety  
requirements without “conditions of acceptability”.  
Clearance between conductors and between conductive  
parts of the component power supply and conductors on  
the board in the final product must meet the applicable  
safety requirements. Certain conditions of acceptability  
apply for component power supplies with limited stand-off  
(see Mechanical Information and Safety Certificate for  
further information). It is the responsibility of the installer to  
ensure that the final product housing these components  
complies with the requirements of all applicable safety  
standards and regulations for the final product.  
Galvanic isolation between input and output is verified in an  
electric strength test and the isolation voltage (Viso) meets  
the voltage strength requirement for basic insulation  
according to IEC/EN/UL 60950-1.  
It is recommended to use a slow blow fuse at the input of  
each DC/DC converter. If an input filter is used in the circuit  
the fuse should be placed in front of the input filter. In the  
rare event of a component problem that imposes a short  
circuit on the input source, this fuse will provide the  
following functions:  
Component power supplies for general use should comply  
with the requirements in IEC/EN/UL 60950-1 Safety of  
Information Technology Equipment. Product related  
standards, e.g. IEEE 802.3af Power over Ethernet, and  
ETS-300132-2 Power interface at the input to telecom  
equipment, operated by direct current (dc) are based on  
IEC/EN/UL 60950-1 with regards to safety.  
Isolate the fault from the input power source so as not  
to affect the operation of other parts of the system  
Protect the distribution wiring from excessive current  
and power loss thus preventing hazardous overheating  
Ericsson Power Modules DC/DC converters, Power  
interface modules and DC/DC regulators are UL 60950-1  
recognized and certified in accordance with EN 60950-1.  
The flammability rating for all construction parts of the  
products meet requirements for V-0 class material  
according to IEC 60695-11-10, Fire hazard testing, test  
flames – 50 W horizontal and vertical flame test methods.  
Non - isolated DC/DC regulators  
The DC/DC regulator output is SELV if the input source  
meets the requirements for SELV circuits according to  
IEC/EN/UL 60950-1.