Mechanical Data
On-Card
Off-Card
Dimensions in mm (in)
Connections
Weight
95 gr (3.35 oz)
Pin
Designation
Function
PKA 2432 PIL 112 gr (3.95 oz)
1
RC
Remote control. To turn-on and turn-off the output. It is also used to
adjust the turn-off input voltage threshold.
Case
2
3
4
5
6
NC
–In
+In
Aux
Not connected.
Negative input.
Positive input.
Auxiliary.
Blue anodized self-cooled aluminium chassis
with snap-on cover and with tin plated brass
pins.
NC
–Out 2
–Out 3
Not connected in singles.
Negative output 2 in duals.
Negative output 3 in triples.
Thermal data
Thermal resistance case to ambient
PI-version Rth case-amb. = 5.0 °C/W
PIL-version Rth case-amb. = 4.6 °C/W
7
NC
+Out 2
Not connected in singles.
Positive output 2 in duals and triples.
8
9
–Out 1/Rtn
+Out 1
Vadj
Negative output 1 in singles and duals. Output return in triples.
Positive output 1in all models.
For Off-Card versions (CI) the specification
is valid if mounting surface has Rth<7°C/W
to ambient.
10
Output voltage adjust.
EN/LZT 146 09 R1A © Ericsson Microelectronics AB, June 2000
3