General
Absolute Maximum Ratings
Stress in excess of Absolute Maximum
Ratings may cause permanent damage.
Absolute MaximumRatings, sometimes
referred to as no destruction limits, are
normally tested with one parameter at a time
exceeding the limits of Output data or
Electrical Characteristics. If exposed to stress
above these limits, function and performance
may degrade in an unspecified manner.
Characteristics
min
max
Unit
TC
Case temperature1)
–
45
+115
°C
TS
Storage temperature
–
55
+125
36
°C
V dc
V dc
Ws
V
VI
Input voltage
–
0.5
Isolation voltage (input to output test voltage)
Transient input energy @ TA = +25°C
Remote control voltage (pin 9)
Output adjust voltage (pin 10)
VISO
500
1.3
0
VRC
Vadj
5
Safety
0
VO
V
The PKA 2000 I Series DC/DC power
modules are designed in accordance with
EN 60 950, Safety of information technology
equipment including electrical business equipment
and certified by SEMKO.
1) Corresponding ambient temp. range (TA) at full output power is –45 to +85°C.
The PKA power modules are recognized by
UL and meet the applicable requirements in
UL 1950 Safety of information technology equip-
ment, the applicable Canadian safety require-
ments and UL 1012 Standard for power sup-
plies.
Input TC < TC max
Characteristics
Conditions
min
typ
max
Unit
TC < TCmax
19
32
V
V
I
Input voltage range
19
13
35
18
V
V
A
TC < + 95°C
The DC/DC power module shall be installed
in an end-use equipment and considerations
should be given to measuring the case tem-
perature to comply with TCmax when in
operation. They are intended to be supplied
by isolated secondary circuitry and shall be
installed in compliance with the require-
ments of the ultimate application. If con-
nected to a 24 V DC power system reinforced
insulation must be provided in the power
supply that isolates the input from the ac
mains. The isolation in the DC/DC power
module is an operational insulation in accord-
ance with EN 60 950. One pole of the input
and one pole of the output is to be grounded
or both are to be kept floating.
V
Turn-off input voltage
Inrush current2)
(See Operating Information)
I
off
15
5×10-4
0.8
IIrush
IO = IOnom
2
II
A2s
W
t
PIi
Input idling power
IO=0,TC= 0...+95°C
Input transient peak
current (transient
immunity)
P<1 kW, VC < 50 V,
tr/td =10/1000 ms
20
A
2) PKA 2411 PIL = 30 A, 2×10-3 A2
*) PKA 2432 PIL = 30 A, 5×10-3 A2
s
s
The terminal pins are only intended for con-
nection to mating connectors of internal
wiring inside the end-use equipment.
Environmental Characteristics
The isolation voltage is a galvanic isolation
and is verified in an electric strength test.
Test voltage (VISO) between input and output
is 500 Vdc.
Characteristics
Test procedure & conditions
Frequency
Amplitude
10–500 Hz
0.75 mm
Vibration
The capacitor between input and output has a
value of 10 nF and the leakage current is less
than 1mA @ 26 Vdc.
IEC 68-2-6 Fc
(Sinusoidal)
Acceleration
Number of cycles
10 g
10 in each axis
Peak acceleration
Shock duration
200 g
3 ms
Shock
Flammability ratings of the terminal support
and internal plastic construction details
meets UL 94V-0.
IEC 68-2-27 Ea
(Half sinus)
Peak acceleration
Bump duration
40 g
6 ms
Bump
(Half sinus)
IEC 68-2-29 Eb
Number of bumps
1000 in 6 directions
Temperature
Number of cycles
–40°C to +125°C
10
Temperature
change
IEC 68-2-14 Na
IEC 68-2-3 Ca
Temperature
Duration
40°C
56 days
Damp heat
Temperature
Humidity
Duration
85°C
85% RH
500 hours
Accelerated
damp heat
IEC 68-2-3 Ca
with bias
EN/LZT 146 09 R1A © Ericsson Microelectronics AB, June 2000
2