Input 36-75 V, Output up to 39 A / 468 W
Absolute Maximum Ratings
Characteristics
min
-40
-55
typ
max
Unit
°C
TP1
TS
Operating Temperature (see Thermal Consideration section)
+125
+125
+80
Storage temperature
°C
VI
Input voltage
-0.5
V
+65*
2250
Viso
Vtr
Isolation voltage (input to output test voltage), see note 1
Vdc
V
Input voltage transient according to ETSI EN 300 132-2 and Telcordia GR-1089-
CORE
+100
+80*
VRC
Remote Control pin voltage
-0.3
-0.3
18
V
V
V Logic I/O SALERT, CTRL, SCL, SDA, SA0, SA1
3.6
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and
performance may degrade in an unspecified manner.
Note 1: Isolation voltage (input/output to base-plate) max 750 Vdc.
*) Apply for the narrow input version VI= 40-60 V
Fundamental Circuit Diagram
+IN
+OUT
-OUT
-IN
Auxillary
Supply
Driver
Control
RC
RC isolation