欢迎访问ic37.com |
会员登录 免费注册
发布采购

ELM322_09 参数 Datasheet PDF下载

ELM322_09图片预览
型号: ELM322_09
PDF下载: 下载PDF文件 查看货源
内容描述: OBD ( VPW ),以RS232翻译 [OBD (VPW) to RS232 Interpreter]
分类和应用:
文件页数/大小: 18 页 / 91 K
品牌: ELM [ ELM ELECTRONICS ]
 浏览型号ELM322_09的Datasheet PDF文件第3页浏览型号ELM322_09的Datasheet PDF文件第4页浏览型号ELM322_09的Datasheet PDF文件第5页浏览型号ELM322_09的Datasheet PDF文件第6页浏览型号ELM322_09的Datasheet PDF文件第8页浏览型号ELM322_09的Datasheet PDF文件第9页浏览型号ELM322_09的Datasheet PDF文件第10页浏览型号ELM322_09的Datasheet PDF文件第11页  
ELM322  
AT Commands (continued)  
SR hh  
[ Set the Receive address to hh ]  
Depending on the application, users may wish to  
manually set the address to which the ELM322 will  
respond. Issuing this command will turn off the AR  
mode, and force the IC to only accept responses  
addressed to hh. This could be useful in non-OBD  
applications, or simply while experimenting with a  
network.  
ELM322 AT Commands  
general  
D set all to Defaults  
I show the ID string  
Z reset all  
ST hh  
[ Set Timeout to hh ]  
After sending a request, the ELM322 waits a preset  
time before declaring that there was no response  
from the vehicle (the ‘NO DATA’ response).  
Depending on the application (and priority of the  
request), users may want to modify this timeout  
period before the ELM322 declares that the request  
was a failure. The ST command is used to do that.  
<CR> repeat last command  
responses  
E1/0 Echo on/off  
The actual time used is (approximately) 4 ms x the  
byte value passed as the hexadecimal argument.  
Passing a value of FF thus results in a maximum  
time of about 1020 ms. Values less than 08 will be  
ignored and forced to a value of 8, providing a  
minimum time of 32 ms. The default value is 32  
(decimal 50) providing a timeout of 200 ms.  
H1/0 Headers on/off  
L1/0 Linefeeds on/off  
R1/0 Responses on/off  
PD use Packed Data  
FD use Formatted Data  
ST hh Set Timeout (hh*4ms)  
requests  
Z
[ reset all ]  
SH xx yy zz Set Header  
SR hh Set Rx address  
AR Auto Receive  
MA Monitor All  
MR hh Monitor for Rxer hh  
MT hh Monitor for Txer hh  
This command causes the chip to perform a  
complete reset, as if power were cycled off and then  
on again. All settings are returned to their default  
values, and the chip will be put in the idle state,  
waiting for characters on the RS232 bus.  
AT Command Summary  
Figure 1. ELM322 AT Commands  
Figure 1 (at the right) shows all of the ELM322  
commands in one convenient chart. In order to help  
with the understanding of these, we have grouped  
the commands into three functional areas, but this  
has no bearing on how the commands should be  
used, it is only for clarity. You may find this chart to  
be useful when experimenting with the IC.  
ELM322DSF  
Elm Electronics – Circuits for the Hobbyist  
< http://www.elmelectronics.com/ >  
7 of 18