G4 Digital AC Output Modules  
Specifications (cont.)  
Units  
G4OAC15***  
G4OAC15A***  
G4OAC24***  
G4OAC24A***  
Nominal line voltage  
Output voltage range  
Key feature  
VAC  
VAC  
120  
12–140  
120/240  
24–280  
120  
12–140  
120/240  
24–280  
Current rating:  
At 45 °C ambient  
At 70 °C ambient  
A
A
3
2
3
2
3
2
3
2
UL Motor Load Rating  
A
1.5  
1.5  
1.5  
1.5  
Isolation input-to-output (transient):  
1 ms  
1 minute  
volts  
4000  
1500  
4000  
1500  
4000  
1500  
4000  
1500  
Off-state leakage at nominal volt-  
age (60 Hz)  
mARMS  
5
1.25/2.5  
5
1.25/2.5  
Logic voltage range  
Logic pickup voltage  
Logic dropout voltage  
VDC  
VDC  
VDC  
10.5–16  
10.5  
1
10.5–16  
10.5  
1
19.5–32  
19.5  
1
19.5–32  
19.5  
1
Logic input current at nominal logic  
voltage  
mA  
15  
15  
18  
18  
Control resistance  
(Rc in schematic)  
ohms  
1 K  
80  
1 K  
80  
2.2 K  
80  
2.2 K  
80  
One-cycle surge  
A peak  
micro-  
seconds  
Turn-on time @ 60 Hz  
8.3*  
8.3*  
8.3*  
8.3*  
micro-  
seconds  
Turn-off time @ 60 Hz  
8.3**  
8.3**  
8.3**  
8.3**  
Peak repetitive voltage  
VAC  
mA  
V
500  
20  
500  
20  
500  
20  
500  
20  
Minimum load current  
Output voltage drop maximum peak  
Operating frequency  
1.6  
1.6  
1.6  
1.6  
Hz  
25–65  
25–65  
25–65  
25–65  
V/micro-  
second  
dV/dT-off-state  
200  
200  
200  
200  
snubbed for 0.5  
snubbed for 0.5  
snubbed for 0.5  
snubbed for 0.5  
dV/dT-commutating  
--  
power factor load power factor load power factor load power factor load  
Temperature  
Operating:  
Storage:  
°C  
°C  
-30 to +70  
-30 to +85  
-30 to +70  
-30 to +85  
-30 to +70  
-30 to +85  
-30 to +70  
-30 to +85  
* One-half cycle maximum. Module turns on at the zero volt crossing of the AC sine wave.  
** One-half cycle maximum. Module turns off at the zero current crossing of the AC sine wave.  
*** Not for use with Opto 22 brains.  