CY7C185
Output Current into Outputs (LOW)............................. 20 mA
Maximum Ratings
Static Discharge Voltage........................................... >2001V
(per MIL-STD-883, Method 3015)
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Latch-Up Current.................................................... >200 mA
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Operating Range
Ambient
Supply Voltage to Ground Potential............... –0.5V to +7.0V
Range
Commercial
Industrial
Temperature
0°C to +70°C
–40°C to +85°C
VCC
DC Voltage Applied to Outputs
5V ± 10%
5V ± 10%
in High Z State[3] ............................................ –0.5V to +7.0V
DC Input Voltage[3]......................................... –0.5V to +7.0V
Electrical Characteristics Over the Operating Range
7C185-15
7C185-20
Min. Max.
Parameter
VOH
Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Test Conditions
Min.
Max.
Unit
VCC = Min., IOH = –4.0 mA
2.4
2.4
V
V
V
VOL
VIH
VCC = Min., IOL = 8.0 mA
0.4
0.4
2.2
VCC
+
2.2
VCC +
0.3V
0.8
+5
0.3V
0.8
+5
VIL
IIX
Input LOW Voltage[3]
Input Load Current
–0.5
–5
–0.5
–5
V
GND ≤ VI ≤ VCC
µA
µA
IOZ
Output Leakage
Current
GND ≤ VI ≤ VCC
,
–5
+5
–5
+5
Output Disabled
IOS
Output Short
VCC = Max.,
VOUT = GND
–300
–300
mA
mA
Circuit Current[4]
ICC
VCC Operating
Supply Current
VCC = Max.,
IOUT = 0 mA
130
110
ISB1
ISB2
Automatic
Power-Down Current
Max. VCC, CE1 ≥ VIH or CE2 ≤ VIL
Min. Duty Cycle = 100%
40
15
20
15
mA
mA
Automatic
Power-Down Current
Max. VCC, CE1 ≥ VCC – 0.3V,
or CE2 ≤ 0.3V
VIN ≥ VCC – 0.3V or VIN ≤ 0.3V
Notes:
3. Minimum voltage is equal to –3.0V for pulse durations less than 30 ns.
4. Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
Document #: 38-05043 Rev. *A
Page 2 of 11