LAA108
PERFORMANCE DATA*
Maximum Load Current
vs.Temperature
(IF=5mA)
Turn-Off Time vs.Temperature
Turn-On Time vs.Temperature
(IF=5mA, IL=80mA)
(IF=5mA, IL=80mA)
0.65
0.26
0.24
0.22
0.20
0.18
0.16
0.14
500
450
400
350
300
250
200
150
100
Total Current - Both Poles Operating *
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
Single Pole Operating
* Neither pole to exceed
single pole limits
-40
-20
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
Temperature (ºC)
Temperature (ºC)
Temperature (ºC)
Leakage Current vs.Temperature
Measured Across Pins 5 & 6, 7 & 8
(VL=100V)
Energy Rating Curve
(Single Pole, IF=5mA,TA=25ºC)
Blocking Voltage vs.Temperature
25
20
15
10
5
150
148
146
144
142
140
138
136
134
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0
-40
10μs 100μs 1ms 10ms 100ms 1s
10s 100s
-20
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
Time
Temperature (ºC)
Temperature (ºC)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
R02
4
www.clare.com