LAA108
Absolute Maximum Ratings
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Ratings
Units
VP
Blocking Voltage
100
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
50
V
mA
A
1
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage Input to Output
Operational Temperature
Storage Temperature
150
mW
mW
Vrms
°C
800
3750
-40 to +85
-40 to +125 °C
1
Derate Linearly 1.33 mw/˚C
Derate Linearly 6.67 mw/˚C
2
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25°C
Load Current
Continuous 1
-
IL
-
-
-
-
-
-
300
400
8
mA
Peak
On-Resistance 2
t =10ms
IL=300mA
VL=100VP
ILPK
RON
ILEAK
Ω
4.5
-
Off-State Leakage Current
Switching Speeds
Turn-On
1
μA
tON
tOFF
-
-
-
0.43
0.17
110
3
3
-
IF=5mA, VL=10V
50V, f=1MHz
ms
pF
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current 3
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
Input to Output Capacitance
1
COUT
IL=300mA
-
IF
-
-
0.5
0.3
1.2
-
2
-
mA
mA
V
0.2
0.9
-
IF=5mA
VR=5V
VF
IR
1.4
10
μA
-
CI/O
-
3
-
pF
If both poles operate simultaneously, the load current must be derated so as not to exceed the package total power dissipation value.
2
3
Measurement taken within one (1) second of on time.
For applications requiring high-temperature operation (T>60ºC), an LED drive currrent of 4mA is recommended.
R02
2
www.clare.com