CPC7594
1.3 Absolute Maximum Ratings
1.4 ESD Rating
Parameter
+5 V power supply (V
Battery Supply
Minimum Maximum
Unit
ESD Rating (Human Body Model)
1000 V
)
-0.3
-
7
V
V
V
V
DD
-85
+5
1.5 General Conditions
D
to F
Separation
-5
GND
GND
Unless otherwise specified, minimum and maximum
values are guaranteed by production testing
requirements.
V
+ 0.3
Logic input voltage
-0.3
DD
Logic input to switch output
isolation
-
-
-
320
320
465
V
V
V
Typical values are characteristic of the device at 25° C
and are the result of engineering evaluations. They are
provided for information purposes only and are not
part of the testing requirements.
Switch open-contact
isolation (SW1, SW2, SW3,
SW5, SW6)
Switch open-contact
Isolation (SW4)
Specifications cover the operating temperature range
T = -40° C to +85° C. Also, unless otherwise specified
A
Operating relative humidity
Operating temperature
Storage temperature
5
95
%
all testing is performed with V = 5 V , logic low
DD
dc
-40
-40
+110
+150
°C
°C
input voltage is 0 V and logic high voltage is 5 V .
dc
dc
Absolute maximum electrical ratings are at 25°C.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.