CPC1393
Absolute Maximum Ratings
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Ratings
600
Units
VP
Peak Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
50
V
mA
A
1
Input Power Dissipation 1
Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
100
mW
mW
Vrms
ºC
550
5000
-40 to +85
-40 to +125
ºC
1
Derate Linearly 1.33 mW/ºC
2
Derate Linearly 3.00 mW/ºC
Electrical absolute maximum ratings are at 25ºC
Electrical Characteristics
Parameters
Output Characteristics @ 25°C
Load Current
Conditions
Symbol
Min
Typ
Max
Units
Continuous
-
IL
-
-
-
-
-
-
90
350
50
1
mA
Peak
t=10ms
IL=90mA
VL=600V
ILPK
RON
ILEAK
On-resistance 1
Off-State Leakage Current
Switching Speeds
Turn-On
35
-
Ω
μA
IF=5mA, VL=10V
TON
TOFF
COUT
-
-
-
-
-
5
5
-
ms
pF
Turn-Off
Output Capacitance
IF=0mA, VL=50V, f=1MHz
50
Input Characteristics @ 25°C
Input Control Current
IL=90mA
-
IF
IF
-
0.55
2
-
mA
Input Dropout Current
0.2
0.9
-
-
1.2
-
Input Voltage Drop
IF=5mA
VR=5V
VF
IR
1.4
10
V
Reverse Input Current
μA
Common Characteristics @ 25°C
Input to Output Capacitance
-
CI/O
-
3
-
pF
1
Within 1 second of time.
R03
2
www.clare.com