欢迎访问ic37.com |
会员登录 免费注册
发布采购

0805M390KRR 参数 Datasheet PDF下载

0805M390KRR图片预览
型号: 0805M390KRR
PDF下载: 下载PDF文件 查看货源
内容描述: 氧化锌 [Zinc Oxide]
分类和应用:
文件页数/大小: 9 页 / 247 K
品牌: CERAMATE [ CERAMATE TECHNICAL ]
 浏览型号0805M390KRR的Datasheet PDF文件第1页浏览型号0805M390KRR的Datasheet PDF文件第2页浏览型号0805M390KRR的Datasheet PDF文件第3页浏览型号0805M390KRR的Datasheet PDF文件第5页浏览型号0805M390KRR的Datasheet PDF文件第6页浏览型号0805M390KRR的Datasheet PDF文件第7页浏览型号0805M390KRR的Datasheet PDF文件第8页浏览型号0805M390KRR的Datasheet PDF文件第9页  
TYPE  
MODEL  
PAGE  
4/9  
SMV0805M□□□KRR  
CITATION  
SUBJECT  
DATE Feb. 03, 2009  
C01  
Reliability  
REV.  
3. ENVIRONMENTAL CHARACTERISTICS  
Test method and description  
for 1000 12 hours in a thermostatic bath  
without load and then stored at room temperature and humidity for 1 to 2 hours.  
The change of varistor voltage shall be within 10  
No.  
3.1  
Characteristic  
The specimen shall be subjected to 150  
±
2
±
High Temperature  
Storage  
.
The temperature cycle of specified  
Step  
Temperature  
-40  
Period  
30Min±3  
temperature shall be repeated five times  
and then stored at room temperature and  
humidity for one or two hours. The  
1
2
3
4
±3  
Room Temperature  
125  
Room Temperature  
1~2 hours  
30Min  
1~2 hours  
3.2  
Temperature Cycle  
±2  
±3  
change of varistor voltage shall be within  
10  
and mechanical damage shall be  
After being continuously applied the maximum allowable voltage at 85  
±
2
F
or 1000  
hours, the specimen shall be stored at room temperature and humidity for one or two  
hours, the change of varistor voltage shall be within 10  
The specimen should be subjected to 40 , 90 to 95  
maximum allowable voltage applied for 1000 hours, then stored at room temperature  
and humidity for one or two hours. The change of varistor voltage shall be within 10  
The specimen should be subjected to -40 , without load for 500 hours and then  
stored at room temperature for one or two hours. The change of varistor voltage shall be  
within 10  
± 2  
High Temperature  
Load  
3.3  
3.4  
3.5  
.
±
2
%RH environment, and the  
Damp Heat Load/  
Humidity Load  
%
.
± 2  
Low Temperature  
Storage  
4. TECHNICAL TERM  
No.  
4.1  
Item  
Specifications  
Description  
Operating Temperature  
Range  
Operating temperature range without derating.  
-40to +85℃  
-40to +125℃  
< 50 ns  
Storage Temperature  
Range  
Storage temperature range without voltage applied.  
4.2  
4.3  
Transient Response  
Time  
Time lag between application of surge and varistor's  
"turn-on" conduction action.  
 复制成功!