S/CLP/SIL865970/B/21/04/2004
®
celpac
page 2 / 4GB
Control characteristics (at 25°C)
Input : Ic = f( Uc)
DC
8
6
4
2
0
Paramètre / Parameter
Control voltage : AC control
Control voltage : DC control
Control current (@ Uc )
Release voltage
Symbol Min
Nom Max Unit
Uc
Uc
150
110
3
230
240
240
7
VAC
VDC
mA
V
Ic
Uc off
15
Input LED
green
0
50
100
150
200
250
Input immunity : EN61000-4-4
Input immunity : EN61000-4-5
2kV
2KV
U c (V)
Output characteristics (at 20°C)
Parameter
Conditions
Symbol
Ue
Uemin-max
Up
Typ.
400
24-510
1200
Unit
Load voltage
Operating range
Peak voltage
V rms
V rms
V
Clamping voltage
Zero cross level
Latching voltage
Uclamp
Usync
Ua
820 (@1mA)
V
V
V
20
8
Ie nom
AC-51 nominal current : permanent
AC-53 nominal current
Non repetitive overload current
On state voltage drop (typical value)
Dynamic resistance (typical value)
( see Fig. 2 page 3)
Ie AC-51
Ie AC-53
Itsm
32
12
550
0,9
8
A rms
A rms
A
V
mW
tp=10ms (Fig. 3)
@ 25°C
Vt
rt
Output Power dissipation (typical value)
Pd
0,81xIe+0,08xIe2
W
Thermal resistance between junction to air
Off state leakage current
Minimum load current
Turn on time
Turn off time
Operating frequency range
Off state dv/dt
Rthj/a
Ilk
Iemin
ton max
toff max
f
dv/dt
di/dt
I2t
3,3 (2,5)
K/W
mA
mA
ms
ms
Hz
V/µs
A/µs
A2s
@Ue, 50Hz
<1
5
30
30
0,1-440
500
50
1500
Uc nom DC ,f=50Hz
Uc nom DC ,f=50Hz
Maximum di/dt non repetitive
I2t (<10ms)
Conducted immunity level
Conducted immunity level
Short circuit protection
IEC 1000-4-4 (burst)
IEC 1000-4-5(schocks)
FERRAZ
4kV criterion A
4kV criterion A
gRC 25A/32A/50A/63A 14x51
General characteristics (at 20°C)
Input to output insulation
Output to case insulation
Insulation resistance
Rated impulse voltage
Ui
Ui
Ri
Uimp
4000
4000
100 (@500VDC)
VRMS
VRMS
MW
V
4000
Protection level / CEI529
Pollution degree
-
-
IP20
2
Vibration resistance 10 -55 Hz according to CEI68 :
Shocks resistance according to CEI68 ( on DIN rail / with screws)
Ambient temperature (with no icing or condensation)
Storage temperature (with no icing or condensation)
Ambient humidity
Weight
double amplitude
1,5
30/50
-30 /+80
-30/+100
40 to 85
mm
g
°C
°C
%
-
-
HR
260
g
Conformity
Conformity
EN60947-4-3 (IEC947-4-3)
EN60950 UL/cUL pending
www.celduc.com
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19