SPECIFICATIONS
At TA = +25°C, AVDD = DVDD = +5V, MCLK = 320kHz, REFEN LOW, BIASEN LOW, and external +2.5V reference, unless otherwise specified.
ADS1201U
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
ANALOG INPUT
Absolute Input Voltage Range
0
–10
–5
+5
+10
+5
V
V
V
(1)
With VBIAS
Differential Input Voltage Range
(1)
With VBIAS
–20
See Note 2
+20
V
Input Impedance
Input Capacitance
Input Leakage Current
250(4)
kΩ
pF
pA
nA
8
5
50
1
At TMIN to TMAX
SYSTEM PERFORMANCE
Dynamic Range
10Hz Bandwidth(5)
60Hz Bandwidth(5)
1kHz Bandwidth(5)
60Hz Bandwidth(5)
1kHz Bandwidth(5)
130(6)
120(6)
115(6)
dB
dB
dB
115(6)
Integral Linearity Error
±0.0015
±0.0015
%FSR
%FSR
µV
Offset Error(2)
See Note 7
Offset Drift(3)
1
µV/°C
ppm
µV/°C
dB
Gain Error(2)
See Note 7
Gain Error Drift(3)
Common-Mode Rejection
Power Supply Rejection
1
100
80
At DC
80
dB
REFERENCE
Internal Reference (REFOUT
Drift
Noise
Load Current
Output Impedance
)
2.4
2.5
25
50
2.6
1
V
ppm/°C
µVp-p
mA
Ω
V
µA
V
ppm/°C
mA
Source or Sink
–1
2.0
2
External Reference (REFIN
Load Current
VBIAS Output
)
3.0
2.5
3.45
Using Internal Reference
3.15
3.3
50
Drift
Load Current
10
DIGITAL INPUT/OUTPUT
Logic Family
TTL Compatible CMOS
Logic Levels:
V
V
V
V
IH (MCLK)
IL (MCLK)
OH (MOUT)
OL (MOUT)
IIH = +5µA
IIL = +5µA
IOH = 2 TTL Loads
IOL = 2 TTL Loads
2.0
–0.3
2.4
DVDD +0.3
0.8
V
V
V
V
MHz
0.4
1
MCLK Frequency
0.02
4.75
POWER SUPPLY REQUIREMENTS
Power Supply Voltage
Supply Current
Specified Performance
5.25
V
Analog Current
Digital Current
4.6
0.4
mA
mA
Additional Analog Current
REFOUT Enabled
VBIAS Enabled
No Load
No Load
REFOUT, VBIAS Disabled
1.6
1
25
mA
mA
mW
Total Power Dissipation
40
TEMPERATURE RANGE
Specified Performance
–40
+85
°C
NOTES: (1) This range is set with external resistors and VBIAS (as described in the text). Other ranges are possible. (2) After the on-chip offset and gain
calibration functions have been employed. (3) Re-calibration can reduce these errors. (4) Input impedance changes with MCLK. (5) Assume brick wall digital
filter is used. (6) 20 Log (full scale/rms noise). (7) After calibration, these errors will be of the order of the effective resolution.
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.
®
ADS1201
2