6
■ Basic specifications
Measurement line
: Single phase 2 wire, single phase 3 wire, 3 phase 3 wire
(3V3A is possible), 3 phase 4 wire
[Motor output (Pm) measured] 9603 (optional) external input unit required
Measurement method
:
Digital calculation from measured voltage or pulse signal
Effective when 9603 ch A is torque (any of N/ m, mN/m, kN/m, kgf/m,
:
When using 9600, 9601, 9602 (optional)
Measurement item
kgf/cm), and ch B is r/m
Voltage, current, voltage/current peak, effective/reactive/apparent power,
power factor, phase, frequency, current/power integration, load rate, efficiency.
Display indication range
Calculation algorithm
:
:
0.1% to 130% of 9603 voltage range (polarity not indicated)
Set to required format
When using the 9603 (optional)
Voltage, torque, r/min, frequency, motor output.
When using the 9605 (optional)
[Efficiency measurement]
Calculable factors : Maximum of 3 formats
Calculated items
:
P for each input unit, Pm when combined with 9603
(Items measured with 9605 not allowed)
Harmonic, waveform, voltage fluctuation / flicker measurement function.
Display indication range
:
At the lowest range in the DC mode of Models 9600 & 9602: 0.2% to 130%
At the lowest range in the AC+DC mode of Models 9600 & 9602: 0.5% to 130%
At the 200mA range of Model 9601: 0.5% to 130%
At 0.1% to 130% of all other ranges.
All range is zero suppressed at less than lower % value.
Valid input range for voltage, current, and power is 0.5% to 110%
[D/A output]
Number of channels : 8ch (12 bit D/A converter polarity + 11bit)
Output impedance : 100Ω±5%
Output items
Output voltage : DC±5V/f.s.
Output update rate : 16 times/sec
: Outputs 8 arbitrarily selected items
: 6.4 inch TFT color LCD (640 × 480 dot)
Display
Display resolution
Rectification method
:
:
99999 count (except with integration), 9999999 count (with integration)
Switchable between RMS (true root mean square value) nd MEAN
(average rectified RMS indication) When combined mode DC is
selected, its not possible to switch between them.
a
[FDD]
.
: 3.5-inch, 2HD (1.2MB/1.44MB)
: MS-DOS
Compatible media
Format
Functions
: 8 times/sec.
Display update rate
Combined mode
:
Function for saving and loading settings, and saving
measured values. Function for outputting measured values.
Floppy disk formatting function, file renaming and deleting
: DC, AC + DC, AC (AC only when used in combination
with 9601 or 9602 + AC clamp-on sensor)
: FAST (0.1 sec.), MID (0.8 sec.), SLOW (5.0 sec.)
(Time required for stabilization to within ±1% when input is changed
from 0% to 90%, or 100% to 10% of range.)
: OFF / 500Hz / 5kHz / 300kHz (-3dB) For 9601, 5k
/ 300kHz not available.
Analog response time
[Interface]
GP-IB
RS-232C
:
:
Conforms to IEEE-488.1 1987, with reference to IEEE-488.2 1987
Start-stop synchronous, with baud rate of 2400 or 9600 bits/sec
Low pass filter
: OFF / 200Hz (-3dB)
: Voltage / current / active power
DC ±5V f.s (1000V range is DC ±3.333 V f.s.)
Monitor output : Voltage / current: 1Vrms f.s. (1000V range is 0.6667 Vrms f.s.)
Polarity detection regulation filter
[External Control]
Analog output
:
Integration start / stop control, Integration data reset, External
A/D (For display update when power meter display is in hold mode)
Functions
,
Manual print control, FD save control
[Voltage/ Current/ Active power measurement]
Control signal level
:
From 0 / 5V logic signal or short//open contact signal
Measurement range : See Page 5 specifications for individual input units
[Other functions]
[Integration measurement]
: PT/CT ratio Set range 0.0001 to 10000
: Time average (set interval time, timer time, and average of
realtime control time)
Moving average (number of samples: 8/16/32/64)
Exponential average (attenuation factor: 8/16/32/64)
Scaling
Averaging
: 64 times/sec
Number of measurements
:
0 to±9999999 TAh / TWh (integration time up to 10,000 hours)
Measurement range
[Power factor/ Phase angle measurement]
Multilingual display : Japanese/English screen display switching
Interval control time (10 sec to 100 hours) in 10 sec increments
When used in combination with FDD or printer, auto select increments
Measurement range
: -1.0000 (lead) to 0.0000 to 1.0000 (lag)
-180˚(lead) to 0.00˚to 180.00˚(lag)
Set time (all types)
:
(
)
[Frequency measurement]
Timer control time (1 min to 10000 hours) in 1 minute increments
Realtime control time, 1 minute increments
: Max. 3ch (selection of voltage or current for arbitrary channel)
Number of channels
Effective input range : 0.5 Hz to 2 MHz
[Harmonic / Flicker measurement] 9605 (optional) required
: Auto / 50Hz/ 500Hz / 50 kHz / 2 MHz
Measurement range
: See Page 4 specifications for 9605
Measurement item
[Wave peak measurement]
Measurement items
Effective Input Range
:
:
Select either voltage or current for each unit(Shows absolute value of max.)
Effective value of sine wave is within effective input permi-
ssible in the range
■ Measurement accuracy(23˚C±5˚C (73˚F ±9˚F), Less than 80% rh, warm up time greater than 1 hour, sine wave input, power factor = 1, in-phase voltage = 0)
: ±1dgt for calculations of each measured value
Max. 7 dgt with respect to values calculated from measure-
ments of items substituted into algorithm
: Within ±0.03% f.s/ ˚C
: Within ±0.05% f.s
: Per accuracy table on page 5
Motor output
Efficiency
V, A, W
Apparent / reactive
:
±
:
±1 dgt. with respect to calculation from measured value (U, I, P)
sum value is max.
±
3dgt.
power
:
:
:
:
±
1dgt with respect to values calculated from measurements ( I, P)
Integration
Thermal coefficient
Effect of in-phase
voltage
Effect of power factor
Actual time
D/A output
Analog output
Monitor output
Max.
Max.
±
3dgt with respect to values calculated from measurements (U, I, P)
3dgt with respect to values calculated from measurements (U, I, P)
Power factor
Phase angle
Frequency
±
(1000 Vrms, 50/60Hz, between shorted voltage input terminals and case)
±
0.1% rdg.
input between 10% to 130% of U/I range
1% (at 0.5Hz to 1kHz) 2% (at 1kHz to 10kHz)
(at 10kHz to 100kHz)
±1 dgt. (0˚C to 40˚C(32˚F to 104˚F), for sine wave
: ±0.15% f.s (power factor = 0)
)
: ±25ppm ±1dgt. (0 to 40˚C (73˚F to 41˚F)
: Display accuracy - ±0.2% f.s
: Display accuracy - ±0.2% f.s
)
:
±
,
±
, ±10%
Wave peak
: Display accuracy - ±0.2% f.s (less than 100kHz)
Display accuracy - ±3dB (100k to 1MHz)
■ General Specifications
: Indoors, altitude to 2000 m
: Safety
EN61010-1: 2001
: EMC
Location for use
Certifications
:
Power meter, 0˚Cto 40˚C (32˚F to104˚F), rh below 80%(no condensation)
˚C to 40˚C (41˚F to 104˚F), rh below 80%
Ambient use humidity
When using FDD / printer,
5
:
-10˚C to 50˚C (14˚F to 122˚F)
,
rh below 80% and no condensation
EN61326
EN61000-3-2: 2000
EN61000-3-3: 1995+A1: 2001
AC100V/120V/200V/230V (switched automatically), 50/60Hz
: 150VA max.
Approx 430 W ✕150 H ✕ 370 D mm, Approx13 kg
(Approx 16.93ʺ(W ) 5.91ʺ (H)14.57ʺ (D), Approx 458.6 oz.)
(in configuration including 9600 5 6ch, 9603, 9604)
: 1997+A1: 1998+A2: 2001 class A
Ambient storage humidity
Insulation resistance
: More than 100MΩ from DC500V
Greater than 50M( at DC500V between U/I input terminal and
unit case, between U/I input terminal and power supply plug
(for the 9600/9601), between U input terminal and clamp input
terminal, between U input terminal and unit case, and between
U input terminal and power supply plug (for 9602)
:
Power supply
Maximum rated power
Dimensions, mass
:
:
AC5.55kV between U/I terminal and unit case, between U/I
terminal and power supply plug (for 9600 and 9601), between U
terminal and clamp input terminal, between U terminal and unit
case, between U input terminal and power supply plug (for 9602)
Withstand voltage
(50/60 Hz, 1 minute)
(Not including projections such as terminals, feet, and handles)
: Power cord 1, ground adapter (3P to 2P) 1,
connector 1
Accessories