Applications of 3193  
Support up to Harmonic / Flicker analysis when using the optional 9605 HARMONIC / FLICKER MEASUREMENTS UNIT  
.
Graph Display of Harmonics  
Voltage, current and power  
can be analyzed and displayed  
by bargraphs of harmonic  
amplitude, content and phase  
angle.Voltage, current and power  
can be displayed simultaneously  
for a single channel, or a single  
parameter can be displayed  
simultaneously for each of three  
channels.  
List Display of Harmonics  
The harmonic list display  
shows the amplitude, pro-  
portion, phase angle and  
distortion for each harmonic  
of voltage, current and power.  
Displaying only proportion,  
or two parameters simul-  
taneously, such as amplitude  
and phase angle, is selectable.  
Vector Display of Harmonics  
The harmonic vector display  
shows the voltage, current and  
phase angle for each harmonic,  
making clear the voltage-  
current phase relationship.  
Waveform Display  
The waveform display shows  
one cycle of the voltage and  
current waveforms. RMS and  
peak values can be displayed  
along with voltage and current  
waveforms, or voltage and  
current waveforms for up to  
three channels can be displayed  
at the same time.  
Flicker Measurement Display  
Displays data during measurement  
in real-time. Display can also be  
switched to D measurement and  
"Pst" value.  
Monitor Display  
The relative "d" voltage change  
∆V/V and the instantaneous  
flicker value "S(t)" can be  
displayed in a time series,  
so past variations are clearly  
displayed.  
9605 Specifications (optional)  
:
Every 1 window (except during communications with other devices)  
Update rate  
: List, graph, vector and waveform  
: Harmonic levels; at 45 to 66 Hz  
Voltage/current: ±0.5%rdg.±0.05% f.s.  
Screen displays  
: Installs in the 3193 main unit  
Installation  
3
Accuracy*  
: Single-phase 2- and 3-wire, three-phase 4-wire  
: Up to 3 channels within channels 1 to 6, depending  
on 3193 wiring mode  
Measurement lines  
No. of channels  
Active power: ±1.0%rdg.±0.1% f.s.  
For 45 to 66-Hz fundamental, effective input is 0.1 to 110%  
of range, total error of harmonic current when PLL is locked  
is 5% of the limit value or within 0.2% of the rated current  
of the device under test (no limitation with 9602).  
: Floppy disk, RS-232C, GP-IB, printer  
Output functions  
1
Harmonic Waveform Analysis Functions (IEC61000-3-2* )  
:
Fundamental frequency: 1 to 440 Hz  
PLL system (5 to 440 Hz , external clock system (1 to 5 Hz)  
Measurement range  
2
)
Flicker Measurement Function (IEC61000-3-3  
*
)
: Up to 50th harmonic (with 1 to 250 Hz fundamental)  
: 16 cycles (for 40 to 70 Hz fundamental)  
: Rectangular tiling (no gap between or overlap of windows)  
: 512 points (for 40 to 70 Hz fundamental)  
: Up to 4 (current), and up to 3 (voltage)  
Orders analyzed  
Window width  
Windowing type  
Amount of data analyzed  
Crest factor  
:
:
Fundamental frequency; 45 to 66 Hz, PLL synchronization system  
dc (relative constant voltage change), d max (max. relative constant  
Measurement range  
Analysis items  
voltage change), d(t)200ms (relative voltage change per time), P0.1/  
P1s/ P3s/ P10s and 30s (cumulative probability), Pst (short-term flicker  
value), Plt (long-term flicker value)  
:
Harmonic level, percentage and phase angle of each order  
Measurement items  
of harmonic wave for each of voltage, current and power.  
Total up to 50th harmonic (of 40 to 70 Hz fundamental) for  
voltage, current and power. Total harmonic distortion for  
voltage and current (THD-F and THD-R)  
:
:
Measured value, CPF, Pst list, Monitor  
Screen displays  
3
Accuracy*  
Within ±5% rdg. of limit on the limit curve line (Pst = 1) specified  
for voltage fluctuation in IEC60868-0 (d measurement is the same)  
RMS voltage 0.5%rdg. 0.05%f.s. (45Hz~66Hz)  
*2. Decision function not included.  
Measurement of voltage, current, active power, peak voltage  
and peak current values of the fundamental  
±
±
*3. The reading accuracy of the input unit must combined with the analysis accuracy shown above. When  
used with a clamp sensor, accuracy and frequency characteristics of the clamp must be added to the  
analysis accuracy above.  
*1. The 9605 does not support limit values, so pass/fail decisions based on limit values, classification  
of special waveforms (A to D) and 2.5-minute measurement function for measuring transient harmonic  
currents are not supported.  