AWT6222  
Table 4: Electrical Specifications - Cellular Band  
(TC  
= +25 °C, VBATT = VCC = +3.4 V, VENABLE = +2.4 V, 50 system)  
COMMENTS  
PARAMETER  
MIN  
TYP  
MAX  
UNIT  
P
OUT  
V
MODE1  
25.0  
14.0  
28  
15.5  
30.5  
18.0  
+29 dBm  
+16 dBm  
0 V  
2.4 V  
Gain  
dB  
dBc  
dBc  
%
-
-
-41  
-42  
-37.5  
-37.5  
+29 dBm  
+16 dBm  
0 V  
2.4 V  
ACLR1 at 5 MHz offset (1)  
ACLR2 at 10 MHz offset  
Power-Added Efficiency (1)  
-
-
-62  
-57  
-48  
-48  
+29 dBm  
+16 dBm  
0 V  
2.4 V  
37  
19  
41  
22  
-
-
+29 dBm  
+16 dBm  
0 V  
2.4 V  
Quiescent Current (Icq)  
Low Bias Mode  
-
-
-
-
8
0.35  
0.5  
3
13  
0.8  
0.8  
5
mA  
mA  
mA  
mA  
VMODE1 = +2.4 V  
Mode Control Current  
Enable Current  
through VMODE pins, VMODE = +2.4 V  
through VENABLE pin  
BATT Current  
through VBATT pin, VMODE1 = 2.4 V  
V
V
BATT = +4.3 V, VCC = +4.3 V,  
ENABLE = 0 V, VMODE1 = 0 V  
Leakage Current  
-
<1  
5
µA  
-
-
-134.5 -133  
-139 -137  
P
P
OUT = +29 dBm, VMODE1 = 0 V,  
OUT = +16 dBm, VMODE1 =2.4 V  
Noise in Receive Band(2) (Band 6)  
Noise in Receive Band(3) (Band 5)  
dBm/Hz  
dBm/Hz  
-
-
-134.5 -133  
P
P
OUT = +29 dBm, VMODE1 = 0 V,  
OUT = +16 dBm, VMODE1 =2.4 V  
-139  
-137  
Harmonics  
2fo  
3fo, 4fo  
-
-
-45  
-50  
-30  
-35  
P
OUT < +29 dBm  
dBc  
VSWR  
dBc  
Input Impedance  
-
-
-
-
2:1  
Spurious Output Level  
(all spurious outputs)  
-70  
See Note 4  
Load mismatch stress with no  
permanent degradation or failure  
8:1  
-
-
VSWR Applies over full operating range  
Notes:  
(1) ACLR and Efficiency measured at 836.5 MHz.  
(2) 875 MHz to 885 MHz.  
(3) 869 MHz to 894 MHz.  
(4) POUT < +29 dBm, In-band load VSWR < 5:1, Out-of-band load VSWR < 10:1. Applies over all operating conditions.  
Data Sheet - Rev 2.1  
4
11/2008