 浏览型号2032-X0043HX-25D的Datasheet PDF文件第1页浏览型号2032-X0043HX-25D的Datasheet PDF文件第2页浏览型号2032-X0043HX-25D的Datasheet PDF文件第3页浏览型号2032-X0043HX-25D的Datasheet PDF文件第4页浏览型号2032-X0043HX-25D的Datasheet PDF文件第5页浏览型号2032-X0043HX-25D的Datasheet PDF文件第7页浏览型号2032-X0043HX-25D的Datasheet PDF文件第8页浏览型号2032-X0043HX-25D的Datasheet PDF文件第9页  
Safety Isolation System  
ElectroGuard  
Optional Features (continued)  
Note: The time delay feature affects all input devices wired to the  
Expansion Module (Can be ordered separately):  
Expansion Module.  
For applications requiring more  
than the maximum allowable  
Remote Lockout Stations, or  
For Expansion Module(s) Factory Installed:  
Add One of the Following Catalogue Num ber Strings to  
the Safety Isolation System Catalogue Num ber:  
total wire lengths longer than  
those permitted with the  
Remote Lockout Stations.  
Num ber of Ports  
per Expansion  
Module  
Expansion Modules are  
Num ber of  
Expansion Modules  
Catalogue Num ber  
available in 4 or 10 port  
String ➊  
configurations. EachExpansion  
4
-1EUF  
-1EUFTDA  
-1EUT  
Module is wired to a port on the Control Module, and takes the  
connection port that would normally accommodate a Remote  
Lockout Station (see page 12-18 to determine if an Expansion  
Module is required due to wire length considerations).  
One (available on  
Bulletin 2031, 2032,  
or 2033, 110A–  
4 w/time delay  
10  
10 w/time delay  
4
1200A Systems only)  
-1EUTTDA  
-2EUF  
The 23A through 85A systems will accommodate connection of a  
maximum of 4 Expansion Modules, and the 110A through 1200A  
systems will accommodate connection of a maximum of 6  
Expansion Modules.  
Two (available on  
630A – 1200A  
Bulletin 2032 or 2033  
Systems only)  
4 w/time delay  
10  
-2EUFTDA  
-2EUT  
10 w/time delay  
-2EUTTDA  
Certain ampere size Safety Isolation System Power Panels can  
accommodate either 1 or 2 Expansion Modules installed internally.  
In all other instances the Expansion Module(s) must be located  
external to the Safety Isolation System in a suitably rated enclosure.  
e.g. Catalogue Number 2032T-A0630JB-30L becomes Catalogue Number  
2032T-A0630JB-30L-2EUT to indicate a 630A Safety Isolation System that  
includes 2 internally installed 10 port Expansion Modules without the time delay  
feature.  
Open Type Expansion Module for Field Addition  
Am pere Size of Safety Internal Provisions to Accom m odate  
Isolation System  
Expansion Modules  
O pen Type  
23A - 85A  
None  
Description  
Catalogue Num ber  
2030-EUNF  
Provisions to accept one (1) Expansion  
Module (Bulletins 2031, 2032 or 2033)  
4 port  
110A - 420A  
630A - 1200A  
4 port w/ time delay  
10 port  
2030-EUNF-1TDA  
2030-EUNT  
Provisions to accept up to two (2)  
Expansion Modules in Bulletin 2032 or 2033  
combination systems, or one (1) Expansion  
Module in Bulletin 2031 non combination  
systems.  
10 port w/time delay  
2030-EUNT-1TDA  
Requires user supplied enclosure if not installed in the Safety Isolation System  
Power Panel.  
Expansion Modules may be ordered with an adjustable time delay  
feature (1-30 seconds) in order to allow time for the machine  
operator to shut-down drives or other equipment that requires a  
controlled stop after a Remote Lockout Station has been switched to  
the “Offposition. Consult your Rockwell Automation sales office  
for other time settings.  
To order the Status Communication to a remote PLC option installed in an  
enclosed Expansion Module, add one of the following Catalogue Strings to the  
Expansion Module Catalogue Number:  
Com m unication  
Platform  
Num ber of I/O  
Points  
Catalogue  
Num ber String ➊  
Remote I/O  
DeviceNet  
16 points  
16 points  
-1CO M  
Enclosed Expansion Modules are available with optional “Flex”  
modules to provide status communication to a remote PLC.  
Communication can be via DeviceNet or Remote I/O.  
-1DNET  
e.g. Catalogue Number 2030-EUJF becomes Catalogue Number 2030-EUJF-  
1COM to indicate a Type 12 enclosed, 4-port expansion module, with 16 points  
of remote I/O.  
Note: The status communication option allows a remote PLC to receive  
status signals from the Expansion Module. The Expansion Module does  
not accept input signals from DeviceNet or Remote I/O.  
To order the optional enclosed Expansion Module for field addition for North Am erica:  
Catalogue Num ber ➊  
Description  
4 port  
Type 1 Enclosure  
2030-EUAF  
Type12 Enclosure  
2030-EUJF  
Type 4 Painted Enclosure  
2030-EUFF  
Type 4X Stainless Steel Enclosure  
2030-EUCF  
4 port w/ time delay  
10 port  
2030-EUAF-1TDA  
2030-EUAT  
2030-EUJF-1TDA  
2030-EUJT  
2030-EUFF-1TDA  
2030-EUFT  
2030-EUCF-1TDA  
2030-EUCT  
10 port w/time delay  
2030-EUAT-1TDA  
2030-EUJT-1TDA  
2030-EUFT-1TDA  
2030-EUCT-1TDA  
To order the optional enclosed Expansion Module for field addition for outside of North Am erica:  
Catalogue Num ber ➊  
Description  
IP30 Enclosure  
2030-EUPF  
IP54 Enclosure  
2030-EUHF  
IP65 Enclosure  
2030-EUW F  
4 port  
4 port w/ time delay  
10 port  
2030-EUPF-1TDA  
2030-EUPT  
2030-EUHF-1TDA  
2030-EUHT  
2030-EUW F-1TDA  
2030-EUW T  
10 port w/time delay  
2030-EUPT-1TDA  
2030-EUHT-1TDA  
2030-EUW T-1TDA  