Safety Isolation System  
ElectroGuard  
Combination Systems with Fusible Disconnect Switch  
Product Selection: For North America (see page 12-19 for Ordering Instructions)  
3-Phase Max. Hp  
Rating (60Hz)  
Catalogue Num ber ➊  
Fuse  
Clip  
Type 12 Motor  
Control Centre  
Type Enclosure  
(with bussing)  
Typ e 4  
Typ e 4 X  
W atertight  
Stainless Steel  
Enclosure  
Am p.  
Typ e 1 Ge ne ral  
Purpose  
Enclosure  
W atertight  
Painted Steel  
Enclosure  
Rating 200 230 460 575 Rating/  
Type 12 Dust  
tight Enclosure  
(AC-3)  
V
V
V
V
Ty p e ➊  
30A  
2032-A0023A -24J 2032-A0023J -24J 2032-!0023J -24J 2032-A0023F -24J 2032-A0023C -24J  
2032-A0023A -25J 2032-A0023J -25J 2032-!0023J -25J 2032-A0023F -25J 2032-A0023C -25J  
2032-A0043A -25J 2032-A0043J -25J 2032-!0043J -25J 2032-A0043F -25J 2032-A0043C -25J  
2032-A0043A -26J 2032-A0043J -26J 2032-!0043J -26J 2032-A0043F -26J 2032-A0043C -26J  
2032-A0085A -26J 2032-A0085J -26J 2032-!0085J -26J 2032-A0085F -26J 2032-A0085C -26J  
2032-A0085A -27J 2032-A0085J -27J 2032-!0085J -27J 2032-A0085F -27J 2032-A0085C -27J  
2032-A0110A -27J 2032-A0110J -27J 2032-!0110J -27J 2032-A0110F -27J 2032-A0110C -27J  
2032-A0110A -28J 2032-A0110J -28J 2032-!0110J -28J 2032-A0110F -28J 2032-A0110C -28J  
2032-A0180A -27J 2032-A0180J -27J 2032-!0180J -27J 2032-A0180F -27J 2032-A0180C -27J  
2032-A0180A -28J 2032-A0180J -28J 2032-!0180J -28J 2032-A0180F -28J 2032-A0180C -28J  
2032-A0210A -28J 2032-A0210J -28J 2032-!0210J -28J 2032-A0210F -28J 2032-A0210C -28J  
2032-A0300A -28J 2032-A0300J -28J 2032-!0300J -28J 2032-A0300F -28J 2032-A0300C -28J  
2032-A0300A -29J 2032-A0300J -29J 2032-!0300J -29J 2032-A0300F -29J 2032-A0300C -29J  
2032-A0420A -29J 2032-A0420J -29J 2032-!0420J -29J 2032-A0420F -29J 2032-A0420C -29J  
2032-A0420A -30L 2032-A0420J -30L 2032-!0420J -30L 2032-A0420F -30L 2032-A0420C -30L  
2032*-A0630A -30L 2032*-A0630J -30L 2032-!0630J -30L 2032*-A0630F -30L 2032*-A0630C -30L  
2032*-A0630A -34L 2032*-A0630J -34L 2032-!0630J -34L 2032*-A0630F -34L 2032*-A0630C -34L  
2032*-A0860A -34L 2032*-A0860J -34L 2032-!0860J -34L 2032*-A0860F -34L 2032*-A0860C -34L  
2032*-A1200A -34L 2032*-A1200J -34L 2032-!1200J -34L 2032*-A1200F -34L 2032*-A1200C -34L  
Class J  
23  
5
7.5  
15  
15  
60A  
Class J  
60A  
Class J  
43  
85  
10  
25  
40  
15  
30  
40  
30  
60  
30  
60  
100A  
Class J  
100A  
Class J  
200A  
Class J  
200A  
Class J  
110  
75 100  
400A  
Class J  
200A  
Class J  
180  
210  
300  
50  
60  
60 125 150  
75 150 200  
400A  
Class J  
400A  
Class J  
400A  
Class J  
75 125 250 300  
150 175 350 400  
200 250 500 600  
600A  
Class J  
600A  
Class J  
420  
630  
800A  
Class L  
800A  
Class L  
2000A  
Class L  
2000A  
Class L  
860  
250 300 600 700  
450 450 900 900  
2000A  
Class L  
1200  
To order the Tim e Delay feature, add the following Catalogue String to the end of the Cat. No. shown in the table:  
Factory set 30 second time delay feature:  
-1TD  
Example: Catalogue Number 2032-A0180A -27J becomes Catalogue Number 2032-A0180A -27J-1TD to include the time delay feature.  
* Input Power Feed Catalogue Num ber Code  
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.  
Example: Catalogue Number 2032*-A0630J -30L becomes Catalogue Number 2032T-A0630J -30L for a “Top Feed” input power requirement.  
Input Power Feed  
Catalogue Num ber Code  
Top Feed  
Bottom Feed  
T
B
Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.  
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator  
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position.  
Consult your local Rockwell Automation sales office for other time settings.  
12-6