欢迎访问ic37.com |
会员登录 免费注册
发布采购

2030-EUCT 参数 Datasheet PDF下载

2030-EUCT图片预览
型号: 2030-EUCT
PDF下载: 下载PDF文件 查看货源
内容描述: 安全隔离系统 [Safety Isolation System]
分类和应用:
文件页数/大小: 20 页 / 255 K
品牌: ALLEN-BRADLEY [ Allen-Bradley ]
 浏览型号2030-EUCT的Datasheet PDF文件第1页浏览型号2030-EUCT的Datasheet PDF文件第3页浏览型号2030-EUCT的Datasheet PDF文件第4页浏览型号2030-EUCT的Datasheet PDF文件第5页浏览型号2030-EUCT的Datasheet PDF文件第6页浏览型号2030-EUCT的Datasheet PDF文件第7页浏览型号2030-EUCT的Datasheet PDF文件第8页浏览型号2030-EUCT的Datasheet PDF文件第9页  
Safety Isolation System  
ElectroGuard  
Overview  
Status Com m unication Capability to a Rem ote PLC  
Optional Remote I/O via Flex modules. Communication can be  
via the DeviceNet communication platform or the Remote I/O  
communication platform.  
Available from 23-1200 Am peres.  
Specifications  
UL Listed Industrial Control Panel;  
Approvals  
C
US  
TUV Rheinland certified; CE marked  
for all applicable directives  
IEC/EN 60204-1; IEC/EN 60439-1;  
Category 4 to International Standard  
EN 954-1/ISO 13849-1; 98/37/EC  
Machinery Directive; 89/336/EC EMC  
Directive; 73/23/EC Low Voltage  
Directive; Fulfils the function of an  
energy isolating device in accordance  
with the conditions set forth in the  
FedOSHA letter of interpretation  
pertaining to Section 1910.147(b);  
Cal/OSHA 3314.  
Standards  
The ElectroGuard Safety Isolation System is used in place of a  
disconnect switch for Lockout and Tagout (LOTO). It uses power  
contactors and Remote Lockout Stations to accomplish LOTO.  
Isolating the electrical energy usually involves calling an electrician to  
turn “Offthe main disconnecting means. The electrician would  
then perform LOTO of the disconnecting means operating handle.  
Estimated Component Life  
Remote Lockout Station 250,000 operations  
Power Contactors 23A - 85A: 2,000,000 operations  
(Isolation & Grounding) 110A-1200A: 1,000,000 operations  
This same procedure is required to perform cleaning, maintenance,  
setup, lubrication or adjustment. Machines or processes with  
multiple access points may require operator/maintenance  
intervention several times a shift (perhaps as often as 60 times per  
shift).  
Environmental  
Storage Temperature -10°C...+60°C (14°F...140°F)  
Operating Temperature 0°C...+40°C (32°F...104°F) (Ambient)  
Relative Humidity,  
90% Relative Humidity  
Non condensing  
To perform these activities, the operator/maintenance person may  
be required to place part of his or her body into an area not accessed  
during normal operation. This may cause serious or fatal injury if  
LOTO procedures are not followed.  
Power Panel Construction  
Tamper-resistant Control Module  
23A-85A systems support up to 4  
Remote Lockout Stations without an  
Expansion Module  
The ElectroGuard Safety Isolation System allows the machine  
operator to safely and quickly accomplish LOTO with dramatically  
reduced downtime.  
110A-1200A systems support up to 6  
Remote Lockout Stations without an  
Expansion Module  
Provides Energy Isolation  
Control Module with viewing window  
for visual check of status indicator lights  
Power isolation accomplished by means of contactors rather than  
disconnect switches.  
Top and bottom 25.4mm (1.0in)  
conduit entry (removable plug in  
bottom conduit hole)  
Remote Lockout Station  
Construction  
Uses redundant, independent and self-monitoring circuits to  
detect a system fault.  
Sealing provision for tamper-resistance  
Prevents accumulation of faults in order to maintain the integrity  
of the safety system.  
Tamper-resistant design.  
Operating handle accepts up to 3  
padlocks  
4 port—supports up to 4 lockout  
stations  
• allows the systems to  
accommodate up to 24 Remote  
Lockout Stations  
10 port—supports up to 10 lockout  
stations  
• allows the systems to  
accommodate up to 60 Remote  
Lockout Stations  
Window for viewing status indicator  
lights; Sealed for tamper-resistance  
Expansion Module  
Construction  
Convenient Rem ote Lockout Station  
Allows remote isolation of the electrical power to the machine or  
process—machine operator simply turns “Off” a Remote  
Lockout Station.  
A light on the Remote Lockout Station indicates that the three-  
phase power source to the machine or process has been isolated.  
No Light Mea ns No Entr y.  
If a fault occurs in the Safety Isolation System, the “System  
Isolated” light on the Remote Lockout Stations will not  
illuminate.  
Easy Lockout/Tagout.  
Safety Isolation Sys. Inputs  
Standard Inputs from Remote Lockout Stations  
Certified by TUV to m eet requirem ents of Category 4  
Optional Inputs from  
Rockwell Automation  
Safety Products  
Certified by TUV to meet Category 4, the most stringent safety  
category defined within International Standard EN 954-1/ISO  
13849-1.  
Subjected by TUV to rigorous third party testing and verification  
of the Failure Mode & Effect Analysis (FMEA).  
Safety Mats, ➊  
Light Curtains, ➊  
E-Stop Stations, ➊  
Proximity Switches, ➊  
Photo Switches ➊  
System Operational Limits  
+10%, -15% of the line voltage  
Use of any of these input devices will not meet Lockout/Tagout (LOTO)  
requirements.  
12-2