Data Sheet  
February 2001  
L7583A/B/C/D Line Card Access Switch  
The L7583 operates off of a 5 V supply only. This gives  
the device extremely low idle and active power dissipa-  
tion and allows use with virtually any range of battery  
voltage. This makes the L7583 especially appropriate  
for remote power applications such as DAML or FOC/  
FITL or other Bellcore TA 909 applications where  
power dissipation is particularly critical.  
Description (continued)  
The L7583Bxx and L7583Dxx versions provide only an  
integrated diode bridge along with current limiting and  
thermal shutdown (see Figure 2 for version B). This will  
cause positive faults to be directed to ground and neg-  
ative faults to battery. In either polarity, faults are  
reduced by the current-limit and/or thermal shutdown  
mechanisms.  
A battery voltage is also used by the L7583, only as a  
reference for the integrated protection circuit. The  
L7583 will enter an all OFF state upon loss of battery.  
To protect the L7583 from an overvoltage fault condi-  
tion, use of a secondary protector is required. The sec-  
ondary protector must limit the voltage seen at the tip/  
ring terminals to prevent the breakdown voltage of the  
switches from being exceeded. To minimize stress on  
the solid-state contacts, use of a foldback- or crowbar-  
type secondary protector is recommended. With proper  
choice of secondary protection, a line card using the  
L7583 will meet all relevant ITU-T, LSSGR, FCC, or  
UL* protection requirements.  
During power ringing, to turn on and maintain the ON  
state, the ring access switch and ring test switch will  
draw a nominal 2 mA or 4 mA from the ring generator.  
The L7583A/B/C/D device is packaged in a 24-pin,  
plastic DIP (L7583AF/BF/CF/DF) and in a 28-pin,  
plastic SOG (L7583AAJ/BAJ/CAJ/DAJ).  
* UL is a registered trademark of Underwriters Laboratories, Inc.  
Pin Information  
FGND  
1
28 VBAT  
FGND  
NC  
1
2
24 VBAT  
SCR  
AND  
TRIP  
CKT  
NC  
NC  
2
3
4
27  
26  
NC  
NC  
23 NC  
3
22 NC  
NC  
25 NC  
SW1  
SW2  
NC  
4
21 RTESTin  
20 RBAT  
19 RLINE  
18 RRINGING  
17 RTESTout  
TTESTin  
TBAT  
SW1  
SW2  
TTESTin  
5
6
7
24  
23  
RTESTin  
RBAT  
5
TBAT  
SW3  
SW4  
SW3  
SW4  
6
TLINE  
TRINGING  
TTESTout  
NC  
TLINE  
22  
21  
SW5  
RLINE  
SW6  
SW5  
7
8
TRINGING  
NC  
SW6  
SW7  
SW8  
SW7  
8
9
10  
11  
20  
19  
18  
NC  
TTESTout  
NC  
RRINGING  
RTESTout  
LATCH  
SW9  
SW10  
SW8  
LATCH  
INTESTin  
INRING  
9
16  
15  
14  
13  
SW9  
SW10  
10  
11  
12  
VDD  
CONTROL  
LOGIC  
VDD 12  
17  
16  
INTESTin  
CONTROL  
LOGIC  
TSD  
INRING  
TSD  
13  
14  
INTESTout  
DGND  
INTESTout  
15  
DGND  
12-2364.a (F)  
12-2365.d (F)  
Note: Shown with A/C version protection. The 24-pin DIP is avail-  
able with either A/C or B/D version protection.  
Note: Shown with B/D version protection. The 28-pin SOG is avail-  
able with either A/C or B/D version protection.  
Figure 1. 24-Pin, Plastic DIP (600 mil)  
Figure 2. 28-Pin, Plastic SOG  
2
Lucent Technologies Inc.