5SHY 42L6500
Max. on-state characteristic model:
Max. on-state characteristic model:
VT125
VT25
= A +B ×IT +C ×ln(IT +1)+D × IT
= A +B ×IT +C ×ln(IT +1)+D × IT
Tvj
Tvj
Tvj
Tvj
Tvj
Tvj
Tvj
Tvj
Valid for iT = 300 – 30000 A
Valid for iT = 300 – 30000 A
B25
279.5×10-6
259.1×10-6
C25
322.7×10-3
299.1×10-3
D25
-483.3×10-18
407.0×10-18
A25
A125
Max. -281.3×10-3
Typ. -260.7×10-3
B125
394.6×10-6
365.8×10-6
C125
338.2×10-3
313.4×10-3
D125
822.5×10-18
500.3×10-18
Max. -220.9×10-3
Typ. -204.8×10-3
Fig. 3 GCT on-state voltage characteristics
Fig. 4 GCT on-state voltage characteristics
Fig. 5 Surge on-state current vs. pulse length, half-
Fig. 6 Surge on-state current vs. number of pulses,
sine wave
half-sine wave, 10 ms, 50 Hz
ABB Switzerland Ltd, Semiconductors reserves the right to change specifications without notice.
Doc. No. 5SYA1245-00 Aug 07
page 5 of 9