Absolute Maximum Ratings*
Parameter
Symbol
Min
-0.3
Max
7
Units
V
1
2
3
4
5
6
VDD - VSS
Voltage on Digital Inputs
Voltage on Digital Outputs
Current at Digital Outputs
Storage Temperature
Package Power Dissipation
VI
VO
IO
VSS-0.3
VSS-0.3
VDD+0.3
VDD+0.3
40
V
V
mA
°C
W
TS
PD
-65
+150
2
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Recommended Operating Conditions - Voltages are with respect to ground (VSS ) unless otherwise stated.
Characteristics
Sym
Min Typ ‡ Max
Units
°C
V
Test Conditions
1
2
3
Operating Temperature TOP
-40
4.75
0
+85
5.25
VDD
Positive Supply
Input Voltage
VDD
VI
V
‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
DC Electrical Characteristics - Voltages are with respect to ground (V SS ) unless otherwise stated.
Characteristics
Sym
Min Typ‡ Max Units Test Conditions
Inputs
1
2
3
4
5
Supply Current
Input High Voltage
Input Low Voltage
Input Leakage
Input Pin Capacitance
IDD
VI H
VI L
II L
6
10
mA
V
Outputs unloaded
2.0
0.8
5
V
µA
pF
VI between VSS and VDD
CI
8
Outputs
6
7
8
9
Output High Voltage
Output High Current
Output Low Voltage
Output Low Current
VOH
IOH
VOL
IOL
2.4
10
V
IOH = 10 mA
15
10
8
mA
V
Sourcing. VOH=2.4V
IOL = 5 mA
0.4
5
5
mA
µA
pF
Sinking. VOL = 0.4V
VO between VSS and VDD
10 High Imp. Leakage
IOZ
11 Output Pin Capacitance CO
‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
Figure 11 Output Load Test
Test Point
VDD
S1 is open circuit except
when testing output levels
or high impedance states.
RL
Output
Pin
S1
S2 is switched to VDD or
VSS when testing output
levels or high impedance
states.
S2
CL
VSS
VSS
8
© IMP, Inc.