Electrical Specifications,
Z
O
= 50Ω
Symbol
f
IL
IL
IL
∆S21
S21
S21
S21
S21
S11, S22
Pin max
Parameter
Passband
Insertion Loss 1850-1855 MHz
Insertion Loss 1855-1905 MHz
Insertion Loss 1905-1910 MHz
Ripple, 1850-1910 MHz
Min Rejection, 1930-1990 MHz
Min Rejection, 10-1800 MHz
Min Rejection, 1990-3820 MHz
Min Rejection, 3820-5730 MHz
In-band Return Loss
Safe Input Power Level
Units
MHz
dB
dB
dB
dBm
dB
dB
dBm
dBm
dB
dBm
25°C
Min Typ Max
1850
2.0
1.5
2.5
1910
3.5
3.0
3.5
2.5
33
37
25
30
15
9.0
20
11
-30° to +25°C
Min Typ Max
1850
1910
3.7
3.0
3.2
25° to +70°C
Min Typ Max
1850
1910
3.2
3.0
3.7
33
33
9.0
20
11
9.0
20
11
Absolute Maximum Ratings
[2]
Parameter
Operating Temperature
[1]
Storage Temperature
[1]
Unit
°C
°C
Value
–30 to +85
-30 to +100
Notes:
1. Temperature is defined at case T
C
, the
temperature of the underside of the filter
where it makes contact with the circuit board.
2. Specifications are guaranteed over the given
temperature range. Operation in excess of
any one of these conditions may result in
permanent damage to the device.
Typical Performance,
25°C, Z
O
= 50Ω
0
0
-10
-1
ATTENUATION (dB)
ATTENUATION (dB)
-20
-2
-30
-3
-40
-4
-50
1.7
1.80
1.90
FREQUENCY (GHz)
2.00
2.10
-5
1.83
1.85
1.87
1.89
1.91
1.93
FREQUENCY (GHz)
Figure 1. Attenuation vs. Frequency.
0
Figure 2. Insertion Loss vs. Frequency.
0
-10
ATTENUATION (dB)
RETURN LOSS (dB)
-4
-20
-8
-30
-12
-40
-16
-50
0
1.0
2.0
3.0
4.0
5.0
6.0
FREQUENCY (GHz)
-20
1.83
1.85
1.87
1.89
1.91
1.93
FREQUENCY (GHz)
Figure 3. Attenuation vs. Frequency
(Broadband).
Figure 4. Return Loss vs. Frequency.
2